WIKA operating instructions model TR36
Operating conditions
Ambient temperature range
-40 ... +85 °C [-40 ... +185 °F]
Storage temperature range
-40 ... +85 °C [-40 ... +185 °F]
Climate class (IEC 60654-1)
Cx (-40 ... +85 °C [-40 ... +185 °F],
5 ... 95 % r. h.)
Maximum permissible humidity,
condensation
100 % r. h., condensation allowed
Maximum operating pressure
1) 2)
For protection tube Ø 3 mm [0.12 in]
140 bar [2,030 psi]
For protection tube Ø 6 mm [0.24 in]
270 bar [3,916 psi]
For protection tube Ø 8 mm [0.31 in]
400 bar [5,801 psi]
Salt fog
IEC 60068-2-11
Vibration resistance (IEC 60751)
10 ... 2,000 Hz, 8 g
1)
Shock resistance (IEC 60068-2-27)
50 g, 6 ms, 3 axes, 3 directions, three
times per direction
Ingress protection (IP code)
IP65 per IEC/EN 60529
The stated ingress protection only
applies when plugged in using line
connectors that have the appropriate
ingress protection.
Weight
approx. 0.2 ... 0.7 kg [0.44 ... 1.54 lbs] -
depending on version
1)
Dependent on the instrument version
2) Reduced operating pressure when using a compression fitting:
Stainless steel = max. 100 bar [1,450 psi] / PTFE = max. 8 bar [116 psi]
For further specifications see WIKA data sheet TE 60.36 and the order
documentation.
12. Specifications