Summary of Contents for VS05

Page 1: ...Dial Thermostat Models VS05 INSTALLER USER MANUAL iT600 VS05 Installer User Manual_Layout 1 06 06 2014 10 03 Page...

Page 2: ...rmation Installer Parameters Thermostat Installation Mounting position and installation System grouping and communication System option 1 All programmable thermostats Parameter settings User interface...

Page 3: ...y directive 2004 108 EC Low voltage Directive 2006 95 EC Safety Information Use in accordance with the regulations The SALUSVS05 is to be used for room control of hot water heating systems Inside the...

Page 4: ...e or Complete system Installer parameter settings The SALUSVS05 is equipped with installer paramter section this must only be entered by the installer or comptent Person Changing these parameters Can...

Page 5: ...installation To ensure trouble free operation and efficient control the unit is best positioned in a draft free area and at 130cm from the floor Do not position the thermostat near any heat source beh...

Page 6: ...iveCommunicationcableallowsthethermostats tocommunicatewiththeSALUSVS10 configuredasagroupmaster through the SALUS KL06WC both sold separately The VS05 will follow instructions of the VS10 Bringing ce...

Page 7: ...groups per KL10 wiring centre is two The group selection communication cable must correspond to the group terminals on the KL10WC Please refer to note xx and the KL10 installation guide Group 1 For E...

Page 8: ...t Mounting 1 3 2 60mm Wall Mounting For wall mounting mark and mount the rear case to the wall TheVS05issuitableforwallboxes with a centre hole distance of Gently remove front housing iT600 VS05 Insta...

Page 9: ...put SensorTerminals Can be used for external AIR Floor sensor when configured as thermostat Can also be used for Cylinder thermostat when calling for HW CommunicationTerms 12VDC Two wire twisted pair...

Page 10: ...0 VS05 Installer Manual Installation Thermostat Connections xxxxxxxxxxxxx Optional communication connection 12VBC xxxxxxxxxxx LABEL TEXT iT600 VS05 Installer User Manual_Layout 1 06 06 2014 10 04 Page...

Page 11: ...nals if applicable CommunicationTerminals You are ready to secure the rear housing to the wall box Check that the wiring is completed for 1 2 3 Please use the screws provided Ensuretheorientationarrow...

Page 12: ...Installation parameter setting 12 VS05 Installer Manual 1 2 iT600 VS05 Installer User Manual_Layout 1 06 06 2014 10 04 Page...

Page 13: ...uator once a week 24 hours 7 days PWM output to drive actuator open close Need help Actuator can be normally closed normally open Subject to installer jumper selection Need help 1 2 Parameter setting...

Page 14: ...e 14 VS05 Installer Manual Slide switch must be in A position to follow group masterVS10 LED Indication Temperature Adjustment 5 30 oC Mode Selection iT600 VS05 Installer User Manual_Layout 1 06 06 20...

Page 15: ...ect or see page XX RED Led indicates that power is going to the unit in normal operation The top LED will illuminate when room termperature falls below your required temp Green LED means that the unit...

Page 16: ...e annoyance factor no Led is shown when the Group master is in reduced temperature night time mode See below To adjust reduced temperature offset please refer to page XXXXXX Amber LED means that the u...

Page 17: ...ct or see page XX Blue LED indicates the units is in frost protection mode Frost protection temperature is fixedat Green LED means that the temperature has fallen below the frost protection level the...

Page 18: ...ork as a standalone thermostat To return theVS05 to the group if applicable move the slide switch to A RED Led indicates that power is going to the unit in normal operation The top LED will illuminate...

Page 19: ...be in permanent frost protection To return theVS5 to the group if applicable move the slide switch to A Blue LED indicates the units is in frost protection mode Frost protection Temperature is fixed a...

Page 20: ...CTION CONTROL SWITCH AND RATING Output rating Type Loading Input AGENCY APPOVED VS05 Wired dial thermostat designed for 230v ac heating cooling applications Celsius 0 5 oc 5 0 30 0 oc 5 0 30 0 oc 5oc...

Page 21: ...VS05 Installer Manual 21 XXX iT600 VS05 Installer User Manual_Layout 1 06 06 2014 10 04 Page...

Page 22: ...XXX 22 VS05 Installer Manual iT600 VS05 Installer User Manual_Layout 1 06 06 2014 10 04 Page...

Page 23: ...omthedateofinstallation SALUSControls sole liability for breach of this warranty will be at its option to repair or replace the defective product CustomerName CustomerAddress PostCode TelNo Email Engi...

Page 24: ...L T 44 0 1226 323961 E tech salus tech com Issue Date April 2014 Maintaining a policy of continuous product development SALUS Controls plc reserve the right to change specification design and material...