35
WIKA operating instructions, model PGW23.100.11
EN
14391169.01 10/2020 EN/DE
10. Specifications
LoRaWAN
®
specification
Channel spacing
200 kHz
Bandwidth
125 kHz
Max. output power
14 dBm
Measuring rate
2)
For > -20 °C [-4 °F]
Adjustable: 10 seconds to transmission rate, but max. 18 hours
For ≤ -20 °C [-4 °F]
Adjustable: 1 minute to transmission frequency, but max. 18 hours
Transmission rate
3
⁾
Adjustable: 1 minute to 7 days (maximum transmission rate limited
by ETSI EN300 220
4)
)
Safety
Full end-to-end encryption
→ Link: https://lora-alliance.org/sites/default/files/2019-05/lorawan_
security_whitepaper.pdf
1) The range depends on the topography. 10 km can be achieved in free field conditions and with a spreading factor of 12.
2) As-delivered condition: 1 measured value per minute (adjustable via the IIoT platform only).
3) As-delivered condition: 1 transmission per 30 minutes (adjustable via the IIoT platform only).
4) The maximum transmission frequency and duty cycle comply with the standard ETSI EN300 220.
This radio device may be used in EU and EFTA countries.
It may only be used in other countries if the EU declaration of conformity is
valid there and the country recognises ERC recommendation 70-03 on the
use of frequencies.
Check whether these approvals apply to your country. It is not permitted to
use the instrument in countries without valid LoRaWAN
®
radio approval.
10.2 Certificates (option)
Certificates
Certificates
2.2 test report per EN 10204 (e.g. state-of-the-art manufacturing, indication
accuracy)2.2 test report per EN 10204 (e.g. state-of-the-art manufacturing,
indication accuracy)
Calibration
1)
3.1 inspection certificate per EN 10204 (e.g. indication accuracy)
1) Calibrated in vertical mounting position with process connection facing downwards
→ Approvals and certificates, see website.
For further specifications see WIKA data sheet PV 42.02 and the order documentation.