14391169.01 10/2020 EN/DE
10. Specifications
Model PGW23.100.11
Permissible temperature
Medium
-40 ... +100 °C [-40 ... 212 °F]
Ambient
-40 ... +60 °C [-40 ... 140 °F]
Ingress protection per
IEC/EN 60529
■
IP54
■
IP65 (instruments with case filling)
Approved battery
Battery model
SAFT LS17500
Battery type
Lithium thionyl chloride battery
Voltage
■
DC 3.6 V
■
Max. 0.2 W
Service life (typical)
5 years
2
⁾
Weight
■
1.1 kg (filled)
■
0.8 kg (unfilled)
1) For wetted materials from Monel to max. 1,000 bar
2) Applies under the following measuring and sending conditions, as well as reference conditions:
Measuring rate: 1 x per minute, sending rate: 1 x per hour, spreading factor: 7, ambient temperature: 20 °C [68 °F], relative
humidity: 65 %, gauge pressure: 1,013 mbar
Radio standards
NFC specification
On-site interface
NFC (near field communication)
Standard
ISO/IEC 15693 type 5 tag
Frequency
13.56 MHz
LoRaWAN
®
specification
LoRaWAN
®
specification
LoRa
®
868 MHz EU
Version
1.0.3
Frequency range
863 - 870 MHz
Transmission power
12 dBm
Range
1)
≤ 10 km
Approved antennas
■
Rigid antenna (Pulse W5017)
■
Antenna with extended cable (Linx ANT-868-ID-2000-SMA)
Antenna gain
■
+2 dBm (rigid antenna (Pulse W5017))
■
+0.6 dBm (antenna with extended cable (Linx ANT-868-ID-
2000-SMA))
Number of channels
10