16
11532319.05 04/2019 EN/DE/FR/ES
EN
WIKA operating instructions pressure gauge, PG43SA-S, PG43SA-C
9.4 Permissible temperature
Place, Situation
Permissible temperature
Ambient
-20 ... +60 °C
Medium
≤ 150 °C
CIP and SIP
150 °C continuously for wetted parts
Autoclaving
1)
≤ 134 °C, 20 minutes
Storage, transport
-30 ... +70 °C
1) only for model PG43SA-S
with option “autoclavable version”
9.5 Temperature effect
Model
Deviation from the reference temperature
(+20 °C) at the measuring system
PG43SA-S
≤ ±0.5 %/10 K of full scale value
PG43SA-C
≤ ±0.8 %/10 K of full scale value
9.6 Ingress protection per IEC/EN 60529
Model PG43SA-S: IP54
Model PG43SA-C: IP66
For further specifications see WIKA data sheets PM 04.15, PM 04.16
and the order documentation.
9. Specifications