11.
Troubleshooting
PROBLEM
CAUSE
ACTION
Fan does not run
1.Power supply cord is not connected
2.The circuit breaker has cut off
1. Connect the power supply cord
2. Reset the circuit breaker when it’s
cooling after 5 minutes
After pressing the
START key, the
compressor
doesn't start but
the fan runs
1.The unit is in high pressure shut off
(Red alarm light turns on)
2.The unit is under low pressure
protection (Green light turns on)
1. Reduce the system pressure
2. The input loop is blocked, reset
after eliminating troubles
3. Check if well connected
4. Turn the
BY-PASS
switch to the
restart position
The compressor
can’t work
1.Output pressure is too high
2. Failure in the motor, or other
electrical components
1.Turn the INPUT valve to position
CLOSE and restart the unit
2. Factory service is required
The compressor
starts but cuts
off within a
few minutes
1.High pressure shuts off due to wrong
operation, such as output valves of
the unit or recovery cylinder are not
open
2.Thermal protector is disconnected,
but axial fan still running
3.The recovery cylinder is full at 80%
capacity
4. Recovery is over and the unit is
under low pressure switching point
1. Read carefully this operating
manual and follow the instructions,
2. The compressor will restart
automatically after the motor is
completely cooled
3. Take a new cylinder and then press
the START key to start the
compressor
4. Refer to step 4.2 k) and l), then
proceed with self-purge operation
Recovery
process is
too slow
1.The pressure inside the recovery
cylinder is too high
2.The compressor seals are worn out
1. Reduce the cylinder temperature
with the Recovery Cylinder Cooling
Method
2. Factory service is required
The unit
doesn't pull
out a vacuum
1.Connecting hoses are loose
2. There is a leakage in the unit
1.Tighten the connecting hoses
2. Factory service is required
Summary of Contents for EASYREC120R100
Page 1: ...Unit portable pour r cup ration recyclage de r frig rant Manuel d utilisation...
Page 29: ...EASYREC120 USER S MANUAL ENGLISH WIGAM 29...
Page 41: ......
Page 42: ......
Page 43: ......