8.
Ordinary maintenance
8.1.
S
PARE PARTS AND ACCESSORIES
n°1
MG111 Filter drier
n°1
XH412 Filter drier
n°1
G19020 Kit of 10 gaskets for flexible hose with ¼” SAE connections
8.2.
P
ERIODICAL OPERATIONS FOR ORDINARY MAINTENANCE
a)
Replace the swivel connections gaskets of the flexible hoses as soon as they show worn marks.
b)
Replace the filter each time a different type of refrigerant is used and at least once every six
months.
9.
Max pressure switch reset
When a pressure of 38,5 BAR is reached, the max pressure switch, which is in the unit, operates by
restraining all functions; the unit will automatically shut itself off and the Red Alarm Light will turn on.
If the compressor needs to be restarted, please find out the cause first, then reduce the internal pressure
below 25 bar. Press the
START
key to restart the compressor.
10.
Technical features
Refrigerants
Category III: R12, R134a, R401C, R406A, R500
Category IV: R22, R401A, R401B, R402B, R407C,
R407D, R408A, R409A, R411A, R411B,
R412A, R502, R509
Category V: R402A, R404A, R407A, R407B, R410A, R507
Power
220-240VAC 50~60Hz
Motor
370 W AC 4 Pole start capacitor running capacitor
Motor speed
1450 rpm@50Hz
1750 rpm@60Hz
Maximal
current draw
5A
8A
Compressor
Oil-less, air-cooled, piston
Automatic
safety shut-off
38.5 bar/3850kPa(558 psi)
Recovery rate
(kg/min)
Category III
Category IV
Category V
Vapor
0.23Kg/min
0.25Kg/min
0.26Kg/min
Liquid
1.57Kg/min
1.81Kg/min
1.85Kg/min
Push/pull
4.6Kg/min
5.57Kg/min
6.22Kg/min
Operating
temperature
0 ~ 40
℃
Dimensions
500 mm×250 mm×350 mm
Weight
17 kg