Technical damage!
Check the appliance/combined appliance for obvious faults before installation.
A defective appliance must not be put into operation.
Position the appliance/combined appliance at its location.
Ensure minimum distances as listed in the installation plan.
3.5.5 Appliance/combined appliance with enclosure
With appliances/combined appliances that are enclosed allround or in-
stalled, the measures stated below must be implemented.
■
Ensure adequate ventilation.
→ The temperature inside the installation space should not exceed 40 °C.
■
Include air vents in the upper front panelling.
→ These should be at least 900 mm wide and 200 mm high.
■
Install an additional fan with a thermostat.
If for hygienic reasons a base cover is requested by the customer, ensure
that the cover is flush with the ground, e.g. by means of a sealing lip. En
-
sure that the cover can also be disassembled for servicing purposes.
3.5.6. Appliance ID
Attach the supplied DIN EN 60335-2-42-compliant label at a height of 1.60 m
above floor level on the appliance where it can be seen clearly.
NOTICE
min. 900 mm
min. 200 mm
NOTICE
Note that the information on minimum spacing refers to device combinations
without accessories. More information can be found in the individual installation
plans.