3.4 Place of installation and surroundings
Risk of burning!
The appliance/combined appliance must be placed such that the installation
area faces a suitable wall.
If the appliance/combined appliance is placed free-standing in a room, the instal-
lation area has to be protected with a suitable cover from interference or being
touched by unauthorised people. This cover must be verified and approved by
WIESHEU GmbH or persons authorised by WIESHEU GmbH.
The appliance must stand on a horizontal, secure, non-tilting base that can take
the weight of the device or the combined appliance.
There is a danger of overloading. The manufacturer’s recommendation in ac-
cordance with the installation plan is to be observed during installation.
Technical damage!
To ensure correct functioning, the appliance/combined appliance must be in-
stalled on dry, frost-proof premises.
The combined system parts must only comprise WIESHEU products or products
approved by WIESHEU GmbH.
Only these products have been thoroughly tested. WIESHEU GmbH accepts no
liability for damage resulting from the use of non-approved products.
The maximum overall height of a combined appliance must not exceed
2265 mm. Otherwise, ergonomic and safe operation of the combined appliance
is not possible.
3.5 Place of installation and distances
To avoid heat accumulation:
■
Set up the appliance/combined appliance at a minimum distance of
20 mm from the side wall.
■
Keep the air vents on the sides and on the back clear.
■
Keep a minimum space above the appliance/combined appliance of
100 mm.
■
We recommend not covering the space under the appliance/combined
appliance.
■
When the appliances/combined appliances are completely installed, vent
the exhaust air forwards.
CAUTION
CAUTION
NOTICE
min. 20 mm
min. 100 mm
3.5.1 Free space next to, below and above the appliance/combined appliance