podis CON flat cable
16
Wieland Electric GmbH | BA000369 (Rev. B) | 02/2016
Pull off the web with the remaining sheath residue
3.5
Termination of the flat cable
After the flat cable has been routed, all free cable ends must be safely terminated and sealed in accord-
ance with IP65. Use the cable end pieces (Z5.562.7553.1) for this purpose. They are composed of a
shorter part (cover) and a longer part, which contains the screws, the seal and the insulation ducts. The
following images illustrate the termination of the flat cable.
Route the stripped end of the flat cable into the end
cap (the openings in the end cap are coded in ac-
cordance with the cable outline)
CAUTION
Due to the required air gaps and creepage distances,
podis
®
CON flat cables must always be terminated by end caps on both
ends.