9
8
4 SPECIFICATIONS
Manufactured to Australian Standard AS60974-1
IEC60974-10 6.3.2 6.3.3.
TERM
WELDARC 200 AC/DC
Rated Input Voltage
220 - 240 V
Power Frequency
50/60 Hz
Rated Input Capacity
7.5 KVA
Generator Capacity
10 KVA
Rated Maximum Supply Current Imax
20 A
Maximum Effective Supply Current Ieff
12 A
Output No Load Voltage
81 V
Supply Main Circuit Breaker
25 A
Supply Cable 2.5mm2 & Plug Rating
15 A
Extension Lead Rating
15 A
VRD Safe
12 V
Rated Output @ 40°C
Stick MMA
160 A @ 26.4 V 30% Duty
88 A @ 23.5 V 100% Duty
TIG
200 A @ 18 V 30% Duty
110 A @ 14.4 Volts 100% Duty
Current Up Slope Time
0 - 10 S
Current Down slope Time
0 - 15 S
Pulse Frequency
DC: 0.2-500 Hz
AC: 0.2-20 Hz
Pulse Ratio Width Adjustment
10 - 90 %
AC Balance Control, Negative
50 - 85 %
AC Frequency
50 - 150 Hz
Arc Force Control MMA
0 - 100 %
Arc Start MMA
0 - 100 A
Post Gas Time
1 - 60 S
Pre Gas Time
0 - 5 S
Cooling Type
Fan on Demand
Efficiency
≥ 80% n
Power Factor
0.99 Cos§