2 Welding Modes
The welding machine has 1 MMA and 4
different TIG welding modes.
2.1 DC STICK
DC Stick mode allows MMA welding with
electrode holder and suitable welding
electrodes.
2.2 STICK Weld Screen Information
2.2.1 Current Adjustment
Operator can adjust the current by rotating
the SELECT knob.
A
Memory
Current
Parameter
Knob
A
8
9
SAFE
VRD
2.2.1 Set Current
2.2.2 VRD
Indication that
OCV is safe
Press right
button for
memory
2.3 Parameter election
Press left button
to return to
home menu
DC Stick
2.2.2 VRD Indication
When VRD is enabled, then open circuit
voltage will be reduced a level less than
35V DC which is compliant with AS1674.2
Category C requirements.
Arc starts can be more difficult with VRD
enabled. The start technique is Touch-
Twist-Lift. If VRD is not suitable for the
application, then VRD can be disabled by a
WIA service agent.
2.3 Stick Weld Parameter Change
Press the SELECT knob to enter the Weld
parameter selection menu.
There are two types of adjustments
possible:
- Weld Arc Parameter
- Machine Function