19
18
The centre panel in Display will now
highlight the selected Functions. Three
machine functions can be changed.
- Trigger mode: 2T or 4T
- Start: HF or Lift
- Remote control: Torch or Foot Control
Rotate the SELECT knob to change the
status of the Function.
Press the SELECT knob to confirm the
selection and move to the next function.
Press the Right hand button to EXIT the menu.
3.3.2.1 Trigger Mode
Trigger mode 2T/4T provides a 2 STEP or
4 STEP trigger control while in TIG mode:
Rotate SELECT knob to Highlight 2T or 4T.
3.3.2.1.1 2T Trigger Mode
In this mode the torch trigger must be
pressed on to initiate welding and held on
until welding is finished. Up slope and down
slope, ignition current and crater current
cannot be used in the 2 STEP.
3.3.2.1.2 4T Trigger Mode
In this mode the torch trigger switch is
pressed to start the arc. After the PRE
FLOW gas time has elapsed, the Arc will
start and the current will stay at the START
CURRENT setting.
When trigger is released the current will
increase to the WELDING CURRENT
setting according to the UP SLOPE time.
Output will continue at WELDING
CURRENT setting.
When the torch trigger is pressed again,
then the weld output will decrease down to
FINAL CURRENT setting according to the
DOWN SLOPE time.
Weld output will remain at FINAL CURRENT
until torch trigger is released, then gas will
flow for POST FLOW time.
NOTE: 4T trigger cannot be selected or
used with Foot Controller.
Fig 3 Latch Mode–4 STEP
Time
Amps
IGNITION
IGNITION
CURRENT
CURRENT
PRE GAS
PRE GAS
POST GAS
POST GAS
UP SLOPE
UP SLOPE
WELDING CURRENT
WELDING CURRENT
DOWN SLOPE
DOWN SLOPE
CRATER
CRATER
CURRENT
CURRENT
Press + Hold
Torch Trigger
Press + Hold
Torch Trigger
Release
Torch Trigger
Release
Torch Trigger
Fig 2 Latch Mode–2 STEP
Time
Amps
PRE GAS
PRE GAS
POST GAS
POST GAS
WELDING CURRENT
WELDING CURRENT
Press + Hold
Torch Trigger
Release
Torch Trigger