9 External Trouble Shooting
Power source has no output and no
wirefeed when gun switch is closed :
‘ON’ indicator light is not illuminated
1 Check equipment is connected to a
functional mains power outlet. Test outlet
using a known working appliance.
‘ON’ indicator light is illuminated
1 The gun switch circuit may be incomplete.
• Check the gun switch for continuity
with an ohm meter when the switch
is pressed. Replace if faulty
• Check the 2 pin receptacles in Euro
adaptor are making contact with the
mating pins from the gun Euro end.
2 Power source may have overheated.
• The Weldmatic welding power
source incorporates an in-built
over-temperature thermostat
which will trip if the welding load
exceeds the operating duty cycle.
The ‘OVERLOAD’ light will be
illuminated. The thermostat will reset
automatically - do not switch the
equipment off as the cooling fan will
assist the resetting of the thermostat
• If problem persists after the cool down
period, call your WIA service agent.
Power source has low weld output
1 Check all electrical connections in the
welding current circuit, including weld
cable, work clamp and gun/cable assembly.