Safety 

Page 

6

 

1.

Transport of equipment containing flammable refrigerants

.

See transport regulations

2.

Marking of equipment using signs

.

See local regulations

3.

Disposal of equipment using flammable refrigerants

.

See national regulations.

4.

Storage of equipment/appliances

.

The storage of 

the 

equipment should be in accordance with the manufacturer's instructions.

5.

Storage of packed (unsold) equipment

.

Storage package protection should be constructed such that mechanical damage to the equipment
inside the package will not cause a leak of the refrigerant charge. The maximum number of pieces of
equipment permitted to be stored together will be determined by local regulations.

6.

Information on servicing

.

1)

Checks to the area

Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary
to

 

ensure that the risk of ignition is minimi

z

ed. For repair to the refrigerating system, the following

precautions shall be complied with prior to conducting work on the system.

2)

Work procedure

Work shall be undertaken under a controlled procedure so as to minimi

z

e the risk of a flammable

gas or

 

vapor being present while the work is being performed.

3)

General work area

All maintenance staff and others working in the local area shall be instructed on the nature of work
being carried out. Work in confined spaces shall be avoided. The area around the workspace shall be
sectioned off. Ensure that the conditions within the area have been made safe by control of
flammable

 

material.

4)

Checking for presence of refrigerant

Explanation of symbols displayed on the unit(For the unit adopts R32/R290 Refrigerant only):

WARNING

CAUTION

CAUTION

CAUTION

This symbol shows that this appliance used a flammable refrigerant. If the refrigerant

 

 

is leaked and exposed to an external ignition source, there is a risk of fire.

This symbol shows that the operation manual should be read carefully.

This symbol shows that a service personnel should be handling this equipment 

with reference to the installation manual.
This symbol shows that information is available such as the operating manual or 

installation manual.

Caution: Risk of fire/flammable materials

Summary of Contents for ARC-148MS

Page 1: ...IONER Congratulations on your new Whynter product To ensure proper operation please read this Instruction Manual carefully before using this product Keep this manual in a safe place for future referen...

Page 2: ...cautions Air Filter Cleaning Unit Cleaning Store the unit when not in use Preparation Design Notice Energy Rating Information Ambient Temperature Range For Unit Operating Exhaust Hose Installation Cho...

Page 3: ...the nameplate located on unit have a qualified electrician install the proper receptacle Install the unit on a flat sturdy surface Failure to do so could result in damage or excessive noise and vibra...

Page 4: ...e the appliance must be disconnected from the supply mains Do not remove any fixed covers Never use this appliance if it is not working properly or if it has been dropped or damaged Do not run cord un...

Page 5: ...uction The appliance shall be stored so as to prevent mechanical damage from occurring A warning that the appliance shall be stored in a well ventilated area where the room size corresponds to the roo...

Page 6: ...rk on the system 2 Work procedure Work shall be undertaken under a controlled procedure so as to minimize the risk of a flammable gas or vapor being present while the work is being performed 3 General...

Page 7: ...th the room size within which the refrigerant containing parts are installed The ventilation machinery and outlets are operating adequately and are not obstructed If an indirect refrigerating circuit...

Page 8: ...the copper pipe work If a leak is suspected all naked flames shall be removed extinguished If a leakage of refrigerant is found which requires brazing all of the refrigerant shall be recovered from th...

Page 9: ...that all refrigerants are recovered safely Prior to the task being carried out an oil and refrigerant sample shall be taken in case analysis is required prior to re use of reclaimed refrigerant It is...

Page 10: ...re that they have been evacuated to an acceptable level to make certain that flammable refrigerant does not remain within the lubricant The evacuation process shall be carried out prior to returning t...

Page 11: ...ll to ensure proper air conditioning The horizontal louver blade should be at least 20 away from obstacles DO NOT cover the Intakes Outlets or Remote Signal Receptor of the unit as this could cause da...

Page 12: ...on older units Federal regulations require manufacturers to calculate cooling capacity based on a specific test procedure which was changed just this year Models manufactured before 2017 were tested...

Page 13: ...ION QUANTITY 1 piece 1 piece 1 piece Window Slider Kit 1 set Clear plastic plug plug is in the upper corner of the plastic bag that holds the user manual 1 piece Foam seal A Adhesive Foam seal B Adhes...

Page 14: ...emperature 1 C 2 F increments or timer hours 0 24 hours This unit is capable of displaying set temperature in Fahrenheit or in Celsius To convert from one to the other press and hold the Up and Down b...

Page 15: ...ssory sold separately under the drain area of the lower drain port Remove the bottom drain plug and let the water drain Replace the drain plug and plug in to resume operation Continuous drainage Fig 1...

Page 16: ...to the necessary length keeping it as short and straight as possible WINDOW KIT INSTALLATION The window kit has been designed to fit most standard vertical and horizontal windows However it may be ne...

Page 17: ...type Security bracket Screws Foam seal C non adhesive type Foam seal A adhesive type Foam seal B adhesive type Security bracket Screws Foam seal C non adhesive type EXHAUST AND INTAKE HOSE INSTALLATI...

Page 18: ...s function mode press the MODE button until the DRY indicator light is displayed Please note that when switching function mode there will be an approxi mately 3 minute transition time In dehumidifying...

Page 19: ...comes on AUTO RESTART In the event of a power outage the air conditioner restarts at the previously set function mode and settings when power is restored CONTROLLING THE AIR FLOW DIRECTION The louvers...

Page 20: ...ays when remote sends signal to unit 3 ON OFF Display Displays when the unit is turned on and disappears when it is turned off 4 Timer On Indicator Displays when TIMER ON is set 5 Timer Off Indicator...

Page 21: ...e washable pre This unit has three air filters the washable pre filter activated carbon filter and lower filter Switch off the air conditioner and remove the washable pre filter and activated carbon f...

Page 22: ...yet because of its time delay The set temperature is too high The internal water reservoir is full and P1 appears on display This unit is designed to work in ambient temperatures of 63 F to 90 F Pres...

Page 23: ...y The unit is not level The surface underneath the unit is uneven Low power voltage Make sure the unit is on hard level and stable surface Move the unit to a location with a level and hard floor Make...

Page 24: ...Use in commercial or industrial applications Damage accidental or otherwise to the product while in the possession of a consumernot caused by a defect in material or workmanship Damage caused by cons...