![Whitmore LUBRICURVE ELECTRO 5 Installation & Maintenance Manual Download Page 16](http://html1.mh-extra.com/html/whitmore/lubricurve-electro-5/lubricurve-electro-5_installation-and-maintenance-manual_977318016.webp)
16
Routing of delivery hoses, Cabinet to blade
10.3.8
As outlined previously there are a number of options to
allow connection to the relevant Blade option. Picture
shows EasiBlade layout with empty bay between end
sleepers.
10.3.9
Hoses are 16mm bore for systems with pump distances
up to 8 metres. The correct type and length of hose will
have been despatched with the system.
10.3.10
Irrespective of hose type the principals of running the hose are similar and shown below
for a typical installation with blades on both rails.
10.3.11
Hoses should be protected within suitable piping when passing under rails across the 4’
10.3.12
Running Rail Systems
Two blades have single hose from cabinet to a T piece centrally between the two
blades.
Four blades have single hose from cabinet to a Y piece near each rail linked in turn to T
piece centrally between each blade pair.
10.3.13
Top of Rail Systems
Two blades have single hose from cabinet to a T piece centrally between the two
blades.
Four blades have single hose from cabinet to a Y piece near each rail linked in turn to T
piece centrally between each blade pair.
10.3.14
Specific hose routing will depend on each site, note, to assist balanced flow:
Main delivery hose runs should be of the same length.
Individual hose lengths between each interconnection should be the same length.
10.4
Fitting the Main Delivery Hoses
10.4.1
Having first filled the reservoir operate the pump by pressing the ‘run’ button until grease
is present at hose tail fitting.
10.4.2
Fit one end of a delivery hose to the hose tail inlet on the Blade with a hose clip and after
routing and filling the delivery hose connect to the hose tails on the outside of the pump.
10.4.3
Repeat the procedure for the other hose (If using a twin chamber pump with two hose
outlets).
10.5
Fill the Hoses and Blade’s
o
The main lubricator pump can be used to pump grease from the reservoir to the Blades.
o
On the Control Panel periodically press the Pump Run button.
o
Continue cycle until grease is evident at all Blade ports.
Summary of Contents for LUBRICURVE ELECTRO 5
Page 30: ...30 ...