background image

DICKSON  Baths  have  evolved  since  1924,  using  the 
ideas,  imagination  and  advice  of  many  in  the  field  of 
physical therapy and physical medicine. Today DICKSON 
is synonymous with quality and is the finest name in the 
application of paraffin.

High Heat Warning Light. 

Indicates the temperature of 

the  bath  is  higher  than  that  considered  safe  and 
comfortable for treatment.

Stainless Steel Tank. 

Paraffin and perspiration have been 

known  to  have  corrosive  properties. All  Dickson  paraffin 
baths are constructed with 22 gage 304 stainless steel with 
a  2B  finish,  which  will  not  corrode  with  heavy  use,  and 
meets the highest standards in sanitizing.

Distinctive  features  of  these  baths  are  detailed  on  the 
succeeding pages, but a few of the more prominent ones 
are:

WHY DICKSON PARAFFIN BATHS?

DICKSON    Paraffin    Baths    are    precise    instruments 
designed to safely facilitate hot paraffin treatments of the 
body extremities so as to relieve the pain and discomfort 
associated with joint diseases and/or injuries. 

Precise  Temperature  Control. 

The  DICKSON  Baths 

operate with a maximum temperature variation of plus or 
minus  1°F  (0.55°C).  This  insures  a  critical  bath 
temperature  and  the  quickest  possible  formation  of  the 
paraffin  “glove”  which  is  so  essential  to  the  paraffin 
treatment,  as  it  quickly  protects  the  immersed  member 
from burns, while allowing a great amount of heat input. In 
other  words,  a  good  paraffin  bath  must  hold  the 
temperature  precisely  so  the  solution  will  immediately 
congeal  around  the  relatively  colder  member  when  it  is 
immersed.

There  are  many  other  features,  but,  again,  a  most 
important one is the renowned DICKSON quality with the 
attendant trouble-free rugged construction.

Light Mahogany Molding. 

(Found on models PB-104 and 

PB-105  only)  These  hard  wood  moldings,  with  a  new 
plastic epoxy finish, insure the patient's protection from the 
heat  of  the  bath  and  surrounding  metal.  They  are 
contoured and provide a comfortable, cool and safe rest for 
the patient's arm or leg. They insulate the tank from the 
atmosphere and thereby minimize heat conduction and do 
contribute to the stability of the bath temperature. These 
moldings, in slightly extending over the inside of the tank, 
also serve as a splash guard or arrester.

Timed   Melting   or   Sanitizing   Temperature   Circuit. 

 

The DICKSON Bath is the only bath having a timed hi-heat 
circuit.  This  simply  allows  the  melting  of  the  paraffin  or 
sanitizing  to  take  place  unattended.  Also,  with  such  a 
switch, the hi-heat cannot accidentally be left in the “on” 
position. Sanitizing is accomplished by the operator turning 
the hi-heat circuit on for an hour at the end of the day. When 
the timer returns to zero, the bath automatically returns to 
treatment temperature, ready for use the next morning.

DICKSON Institutional Bath models are shipped complete 
with pure paraffin, plexiglas bottom slats to keep contact of 
appendages from resting directly on the bottom of the unit  
(PB-104  &  PB-105),  cover  and  thermometer.  They  are 
guaranteed  for  1  year  against  mechanical  or  electrical 
defects.

Integrated  Heating  Elements. 

The  elements  are  an 

integral part of the tank and provide an even flow of heat 
with no dangerous hot spots. Also, in this regard for safety, 
all DICKSON baths have a limit switch on both the hi-heat 
and maintenance circuits which will automatically prohibit 
runaway temperatures.

WHITEHALL MANUFACTURING

 • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A

Phone (800) 782-7706 • (626) 968-6681 • Fax (626) 855-4862 • Web: www.whitehallmfg.com

2

Instructions for Operation and Care of Dickson Paraffin Baths

Relative Humidity: 10% to 100%

ACCEPTABLE TRANSPORTATION AND 

Temperature: +32 ºF to +131 ºF (0 ºC to +55 ºC)

Atmospheric Pressure: No Requirements

STORAGE CONDITIONS:

or to severe physical trauma. Degradation of unit 
function and/or performance may occur.

Note: Unit must not be exposed to ingress of water 

CONDITIONS ACCEPTABLES CONCERNANT LE 
TRANSPORT ET L'ENTREPOSAGE:

Une détérioration des fonctions et/ou du 

rendement de 

l'appareil peut en découler.

Remarque : l'appareil ne doit pas être exposé à une 
infiltration d'eau ou à un traumatisme physique grave.

Température : +32 ºF à +131 ºF (0 ºC à +55 ºC)
Humidité relative : 10 % à 100 %
Pression atmosphérique : aucune exigence

Summary of Contents for Dickson PB-104

Page 1: ...fg com 6900 189 000 INSTRUCTIONS FOR OPERATION AND CARE OF INSTITUTIONAL PARAFFIN BATH P O Box 3527 City of Industry CA 91744 0527 U S A Revised October 2018 PB 104 PB 104B PB 105 PB 105B Division of...

Page 2: ...nouvel appareil avant de l utiliser l EFFECTUER LA MISE LA TERRE de votre appareil DE FA ON APPROPRI E Brancher l appareil dans une prise disjoncteur diff rentiel de fuite la terre DDFT ce qui offre...

Page 3: ...Fuse 6 Wiring Diagram for PB 104 14 Wiring Diagram for PB 105 15 Warranty Info 16 Cleaning the Bath 6 Parts Diagram for PB 105 12 Wiring Diagram for PB 107 13 Paraffin Refills 6 Directions for Treatme...

Page 4: ...e the tank from the atmosphere and thereby minimize heat conduction and do contribute to the stability of the bath temperature These moldings in slightly extending over the inside of the tank also ser...

Page 5: ...ensions 14 1 2 L x 7 W x 10 D 368 L x 178 W x 254 D Tank Capacity 18 lbs 8 16 kgs Electrical Requirements Inlet Voltage 100 120 V Frequency 50 60 Hz 3 8 A Inlet Voltage 200 240 V Frequency 50 60 Hz 1...

Page 6: ...4 Instructions for Operation and Care of Dickson Paraffin Baths DICKSON PARAFFIN BATH MODELS PB 105 PB 105B High Heat Sanitizing Indicator Light Low Heat Treatment Temperature Indicator Light High Hea...

Page 7: ...red 10 to 15 minutes for hands 15 to 30 minutes for arms Because of the high heat input of the paraffin the bath must be used judiciously If circulatory and sensory changes are present the application...

Page 8: ...Bath should be disconnected from the electrical outlet and the drain ring removed The sediment and sludge may then be drained the bottom flushed and the slats cleaned PARAFFIN REFILLS Whitehall Manufa...

Page 9: ...the wax up incrementally by small amounts 10 Old wax not melting properly and hardening over time after continual reuse There is a short circuit in the unit The unit must be opened up for repairs 9 Wa...

Page 10: ...ing x x 15 0710 216 001 Fuse 5 x 20mm 10A Fast Acting x x 16 0710 230 001 Fuse Holder 5 x 20mm x x x x x x 17 6900 130 000 Knob For Timer or Switch x x x x x x 18 6900 135 000 Light Rectangle Green 12...

Page 11: ...stor Assembly 12K 220V x 34 6902 470 001 Resistor Assembly 3K 120V x 35 6902 471 001 Resistor Assembly 12K 220V x 36 6902 374 000 Slat Plexiglass x x 37 6902 424 000 Slat Plexiglass x x 38 6505 546 00...

Page 12: ...A 91744 0527 U S A Phone 800 782 7706 626 968 6681 Fax 626 855 4862 Web www whitehallmfg com 10 Instructions for Operation and Care of Dickson Paraffin Baths DICKSON PARAFFIN BATH MODEL PB 107 24 1 44...

Page 13: ...7 U S A Phone 800 782 7706 626 968 6681 Fax 626 855 4862 Web www whitehallmfg com 11 Instructions for Operation and Care of Dickson Paraffin Baths DICKSON PARAFFIN BATH MODEL PB 104 47 33 20 18 28 6 4...

Page 14: ...U S A Phone 800 782 7706 626 968 6681 Fax 626 855 4862 Web www whitehallmfg com 12 Instructions for Operation and Care of Dickson Paraffin Baths DICKSON PARAFFIN BATH MODEL PB 105 45 18 20 48 17 19 21...

Page 15: ...lmfg com 13 Instructions for Operation and Care of Dickson Paraffin Baths FUSE FUSE BLU BRN YEL GRN BLU BRN GND POWER INLET L N HEATING ELEMENT THERMOSTAT RED LIGHT TIMER CONTROL GREEN LIGHT L200 TWIS...

Page 16: ...B 104 FUSE 1 FUSE 2 BLK WHT YEL GRN WHT WHT GND POWER INLET SK RESISTOR GREEN LIGHT RED LIGHT BLK L N HEATING ELEMENT TIMER CONTROL BLK BLK BLK OPERATING THERMOSTAT LOW TEMP THERMOSTAT HIGH TEMP THERM...

Page 17: ...B 105 FUSE 1 FUSE 2 BLK WHT YEL GRN WHT WHT GND POWER INLET SK RESISTOR GREEN LIGHT RED LIGHT BLK L N HEATING ELEMENT TIMER CONTROL BLK BLK BLK OPERATING THERMOSTAT LOW TEMP THERMOSTAT HIGH TEMP THERM...

Page 18: ...r direct charges caused by defects in the materials or any delay in the repair or replacement thereof This warranty is in lieu of all other warranties expressed or implied Product maintenance instruct...

Reviews: