Manual Version 1.3.1
Manual Part# 18200-LM-0038
5.3 Digital Outputs:
The CPT-1 sends out signals to control or be read by other devices. There are two types of digital outputs, voltage
source or a voltage sink. The CPT-1 will turn on both corresponding voltage source and sink when it turns on an
output. Generally, components that may have a higher current draw should be connected to the voltage sink.
Pin Name
Pin #
Wire Color/
Stripe
Designation
Levels
Note
Digital Output:
Left Solenoid
[DO_0]
26
Orange/
White Stripe
Sink
Relay Open = Not Active
Relay Closed = Active
The CPT-1 will turn
on the left and right
solenoid signals to
control a solenoid-
operated pump. If
using a shuttle-
operated pump
these connections
are not required.
44
Light Green/
Green Stripe
Source
Relay Open = Not Active
Relay Closed = Active
Digital Output:
Right Solenoid
[DO_1]
40
Red/
Green Stripe
Sink
Relay Open = Not Active
Relay Closed = Active
14
White/
Black Stripe
Source
Relay Open = Not Active
Relay Closed = Active
Digital Output:
Left Translated
Cycle Rate
[DO_2]
10
Light Blue
Sink
Relay Open = Not Active
Relay Closed = Active
This is the output to
tell the tool about
the modified cycle
rate. If the tool is
only looking for one
signal indicating a
full cycle rate, only
connect one of these
to the tool.
Otherwise connect
both left and right to
the tool.
29
Brown/
White Stripe
Source
Relay Open = Not Active
Relay Closed = Active
Digital Output:
Right Translated
Cycle Rate
[DO_3]
25
Pink/
Black Stripe
Sink
Relay Open = Not Active
Relay Closed = Active
43
Light Blue/
Green Stripe
Source
Relay Open = Not Active
Relay Closed = Active
Digital Output:
System On
[DO_4]
39
Orange/
Green Stripe
Sink
Relay Open = Not Active
Relay Closed = Active
This is to indicate
that the system is
on. This input is
required when
operating a shuttle
pump. However this
can also be used as
verification that the
system is
operational.
13
Pink
Source
Relay Open = Not Active
Relay Closed = Active
Digital Output:
Leak Alarm
[DO_5]
9
Gray
Sink
Relay Open = Not Active
Relay Closed = Active
This output is to alert
the user that a leak
was detected.
28
Violet/
White Stripe
Source
Relay Open = Not Active
Relay Closed = Active
Digital Output:
Over Speed
Alarm
[DO_6]
24
Light Green/
Black Stripe
Sink
Relay Open = Not Active
Relay Closed = Active
This output is to alert
the user that the
pump was operating
faster than the set
threshold
42
Brown/
Green Stripe
Source
Relay Open = Not Active
Relay Closed = Active
Digital Output:
Under Speed
Alarm
[DO_7]
38
Gray/
Green Stripe
Sink
Relay Open = Not Active
Relay Closed = Active
This output is to alert
the user that the
pump was operating
slower than the set
threshold
12
Light Green
Source
Relay Open = Not Active
Relay Closed = Active
Table 3: List of digital output wiring with designations