White Knight CPT-1 Product Manual Download Page 15

 

 

Manual Version 1.3.1 

Manual Part# 18200-LM-0038 

9 Appendix 1: Complete Wiring Guide Table 

Pin Name 

[Quick Connect Port] 

Pin 

Wire 
Color/Stripe 

Designation 

Levels 

Note 

Power:

  

Source Outputs 

15 

Red/Black 

Power Source 

12-24 VDC 

The voltage input into these 

pins will be the voltage output 

for all Source type output pins. 

27 

Red/White 

Ground Reference 

0 VDC 

Power: 

 

Sink Outputs 

Green 

Power Source 

12-24 VDC 

The voltage input into these 

pins will power the sink type 

output pins. 

11 

Orange 

Ground Reference 

0 VDC 

Power: 

 

Input High 

37 

Violet/Red 

Reference Voltage 
High 

12-24 VDC 

The voltage input into this pin 

will be the reference for all 

digital high inputs. 

Power: 

 

Input Low 

19 

Orange/Black 

Reference Voltage 
Low 

0 VDC 

The voltage input into this pin 

will be the reference for all 

digital low inputs. 

Digital Input: 

 

Remote Left 

[DI_2] 

36 

Yellow/Red 

Reference High VDC 

24 V = Not Active 
0 V = Active 

When one of these 

connections becomes active, 

the CPT-1 will turn on and start 

controlling the pneumatic 

pump. Disconnect the left and 

right inputs from the shuttle 
and connect these signals to 

the appropriate high or low 

voltage reference on the CPT-

1.   

18 

Green/Black 

Reference Low VDC 

0 V = Not Active 
24 V = Active 

Digital Input:

 

Remote Right 

[DI_3] 

Blue 

Reference High VDC 

24 V = Not Active 
0 V = Active 

32 

Gray/Red 

Reference Low VDC 

0 V = Not Active 
24 V = Active 

Digital Input: 

 

End Detect Left, or 

Full Cycle Signal 

[DI_0] 

Brown 

Reference High VDC 

24 V = Not Active 
0 V = Active 

The left end detect is used to 

count each full cycle. If using a 

shuttle operated pump, 

connect a pressure switch or 

end detect sensor to the left 

end detect signal.  

If using a solenoid valve-

operated pump, connect both 

the left and right end detect 

sensors such that the signal is 

active when the sensor is 

triggered.  

33 

Light Green/Red  Reference Low VDC 

0 V = Not Active 
24 V = Active 

Digital Input:

 

End Detect Right 

[DI_1] 

22 

Gray/Black 

Reference High VDC 

24 V = Not Active 
0 V = Active 

Red 

Reference Low VDC 

0 V = Not Active 
24 V = Active 

Digital Input: 

 

Leak Detect Left 

[DI_4] 

21 

Brown/Black 

Reference High VDC 

24 V = Not Active 
0 V = Active 

For systems that do not 

support a leak detect function 

to turn off the pump when 

leaks are detected, leak detect 

signals can be brought into 

these digital inputs. When the 

leak detect signal is active, the 

CPT-1 will stop the pump and 

wait for the reset signal before 

the pump will restart.  

White 

Reference Low VDC 

0 V = Not Active 
24 V = Active 

Digital Input:

 

Leak Detect Right 

[DI_5] 

35 

Pink/Red 

Reference High VDC 

24 V = Not Active 
0 V = Active 

17 

Violet/Black 

Reference Low VDC 

0 V = Not Active 
24 V = Active 

Digital Input:

 

Leak Reset 

[DI_6] 

Violet 

Reference High VDC 

24 V = Not Active 
0 V = Active 

When using a leak detect 

sensor through the CPT-1, it is 

required to connect this leak 

detect signal. This can be wired 

into the tool or to a physical 

button located near the pump.  

31 

Blue/White 

Reference Low VDC 

0 V = Not Active 
24 V = Active 

 

 

Summary of Contents for CPT-1

Page 1: ...Manual Version 1 3 1 Manual Part 18200 LM 0038 CPT 1 Product Manual Manual available online at wkfluidhandling com ...

Page 2: ...Connect 44 Pin HD D Sub to Connectors 3 3 System Overview 3 4 Power and Communication 4 4 1 Powering the CPT 1 4 4 2 Ethernet Connection 5 4 3 RS 232 Connection 5 5 Digital I O Setup 5 5 1 Power Digital Ports 5 5 2 Digital Inputs 5 5 3 Digital Outputs 7 5 4 Wiring Configurations 8 6 PC to CPT 1 Communication 9 6 1 Ethernet Connection 9 6 2 RS 232 Connection 9 7 Software Setup 9 7 1 Installation 9 ...

Page 3: ...ith correct power source b Connect the communication cable correctly Ethernet cables should go from the controller to a network switch not your PC c Install and launch the Smart Control Software d The connections dialog should appear at launch Verify that your controller appears on the list and click the connect button See Section 7 e Once connectivity is verified disconnect from the software and ...

Page 4: ...0 XX 0015 24 VDC Power Supply 1 2 1 CPT 1 Cycle Rate Translator The CPT 1 control box is a small I O communication device that converts the pump s cycle rate to the cycle rate that works with the tool s algorithm The control box has 44 pin HD D Sub Connector Sends and receives digital signals Indicator Lights Show when each digital signal is active Power Port Takes 18 36 VDC input to power the con...

Page 5: ... s cycle rate by a factor set by the user and send the scaled cycle rate back to the tool The CPT 1 can be configured to work with any system setup 2 2 Power Adapter with Crimp Pins 2 6 Quick Connect 44 Pin HD D Sub to Connectors Pin reference start at one from top as shown in image below 2 4 Breakout Board 44 Pin HD D Sub to Screw Terminal 2 3 Cable 44 Pin HD D Sub to Wire Leads 2 5 Din Rail Powe...

Page 6: ...locations POE can now be used The Tool sees the scaled cycle rate from the WK CPT 1 The pump operates in the current mode End Stroke Detect Oscillate or End Stroke Oscillate WK CPT 1 Solenoid Tool Algorithm WK Pump Scaled Cycle Rate Operation Figure 2 Illustration of how the CPT 1 maintains two separate communication loops The CPT 1 will run the pump and calculate its cycle rate shown with black a...

Page 7: ...e not powered by the controller An external power supply is required for the digital ports to be active Use Table 1 for digital port power connections Pin Name Pin Wire Color Designation Levels Notes Power Source Outputs 15 Red Black Stripe Power Source 12 24 VDC The voltage input into these pins power all of the source type outputs The voltage input will equal the voltage output from these ports ...

Page 8: ...s triggered 33 Light Green Red Stripe Low VDC Reference 0 V Not Active 24 V Active Digital Input End Detect Right DI_1 22 Gray Black Stripe High VDC Reference 24 V Not Active 0 V Active 3 Red Low VDC Reference 0 V Not Active 24 V Active Digital Input Leak Detect Left DI_4 21 Brown Black Stripe High VDC Reference 24 V Not Active 0 V Active For systems that do not support a leak detect function to t...

Page 9: ...ol Otherwise connect both left and right to the tool 29 Brown White Stripe Source Relay Open Not Active Relay Closed Active Digital Output Right Translated Cycle Rate DO_3 25 Pink Black Stripe Sink Relay Open Not Active Relay Closed Active 43 Light Blue Green Stripe Source Relay Open Not Active Relay Closed Active Digital Output System On DO_4 39 Orange Green Stripe Sink Relay Open Not Active Rela...

Page 10: ...handle leak detection this can be wired into the CPT 1 Select one column from each section that matches the system configuration and then use the rows in the table to determine how the system should be wired Tool Communication Pump Type Leak Detection End Stroke Detection On Off with Cycle Counter Cycle Counter Only Solenoid Pump Shuttle Pump Tool CPT 1 Digital Input Remote Left From Tool From Too...

Page 11: ...Connection An RS 232 connection can be created through the 9 pin serial port on the box When opening the software the RS 232 port will show as a COM port and will give two baud rate options 19200 and 115000 The default baud rate is 115000 but the slower 19200 baud rate can be selected by placing a jumper on the connection labeled 19 2 on the upper left side of the control box 7 Software Setup 7 1 ...

Page 12: ...ters 6 When done click Save Defaults Note if the settings are not saved new settings will be lost when the controller restarts 7 3 Software Inputs Operation Mode This controller can control the pump in three ways To change between operation modes move the knob to the desired operation mode Simulation Mode Calibration mode runs the pump as a simple timer Simulation mode has two functions 1 Fiber op...

Page 13: ... cycle rate If the scale is less than one the emulated cycle rate will be slower than the actual cycle rate Output Percent The output percent changes the duration of the converted signal as a percent of its duration For example if the signal should stay on until the signal from the opposite side turns on set the output percent to 100 or if the signal should turn off shortly after turning on set th...

Page 14: ...er to another the user should first disconnect from the current connection and then connect to the new connection Command Line Entry This tool enables specific commands to be issued to the controller and check the response sent back from the controller Set IP Address By default the control box is set to look for an IP address to be set from the DHCP network However this tool can be used to force a...

Page 15: ... Input End Detect Left or Full Cycle Signal DI_0 7 Brown Reference High VDC 24 V Not Active 0 V Active The left end detect is used to count each full cycle If using a shuttle operated pump connect a pressure switch or end detect sensor to the left end detect signal If using a solenoid valve operated pump connect both the left and right end detect sensors such that the signal is active when the sen...

Page 16: ...und when closed Relay Open Not Active Relay Closed Active 43 Light Blue Green Source Connect to power when closed Relay Open Not Active Relay Closed Active Digital Output System On DO_4 39 Orange Green Sink Connect To ground when closed Relay Open Not Active Relay Closed Active This is to indicate that the system is on This input is required when operating a shuttle pump However this can also be u...

Page 17: ...Manual Version 1 3 1 Manual Part 18200 LM 0038 Controller Label ...

Page 18: ...Manual Version 1 3 1 Manual Part 18200 LM 0038 10 Appendix 2 Dimensional Diagrams ...

Page 19: ...ur Cycle Rate Translator with different connection methods a power supply or request a specific revision level please select options from the appropriate additional options 1 3 www wkfluidhandling com Revision Level Contact factory for copy exact code activation information Rev 44 male pin to Screw Terminals Connection Method Power Supply P 24V 60W Power Supply Required Configurations Additional O...

Page 20: ...Manual Version 1 3 1 Manual Part 18200 LM 0038 ...

Reviews: