Tr
oubleshooting Guide
Power Requirements
When the WhisperKOOL starts to operate,
it draws several times more power
(amps) during the start-up cycle than it
does during normal operation. Make sure
you have the WhisperKOOL on a
dedicated electrical line at a minimum of
20 amps. See the Product Information
Table on page 7 to find the correct
amperage requirement for your unit.
Make sure that the power line for the
WhisperKOOL does not have any
additional equipment installed on that
circuit. An extra load on the line may be
d r a w i n g p o w e r a w a y f ro m t h e
WhisperKOOL unit. In some cases it may
not be readily apparent that an additional
appliance or electrical device has been
installed on the circuit breaker. In
addition, the unit may not be used on an
electrical line with a Ground Fault
Interrupter (GFI). The WhisperKOOL will
draw more amperage than the GFI will
allow.