MAINTENANCE
22
January 2009 / W-SQ16 for mobile applications / EN
4.2.4
Replacing fuel filter
Filter change depends on contamination of the fuel, but
should be done however, at least every 300 running hours.
Before changing the filter, clamp off the supply line.
Remove the hoses from filter and attach them on the new
filter again. The arrow on the filter housing indicates the
direction of the flow. A clogged filter results in a lack of
output of the generating set.
4.2.5
Replacing oil filter
The oil filter is in front of the service side. Replacement
has to be executed according to the schedule in this
manual. Drain the oil using the sump pump and put some
tissues under the filter.
Fig. 17
1 = Oil filter
A smeer of oil has to be put on the seal of the filter before
fitting the filter. The filter should be fastened manually:
when the rubber touches the metal turn 3/4 further.
4.2.6 Readjustment
V-beltplacing oil filter
The alternator bracket allows for readjust of the V-belt.
Deflections should be 10 mm (refer to fig. 19)
4.2.7
Air filter element
The interval for cleaning of the air filter element (figure 20)
strongly depends on environmental conditions. Check the
condition of the element at least every 500 running hours,
but should be at least every six months.
Fig. 20: Air filter element
4.2.8
Air strainer element
The W-SQ16 for mobile applications is standard supplied
with an air strainer element (figure 21). Strainer change
depends on environmental contamination. Check the air
strainer at least every 500 running hours. The strainer can
be cleaned by washing in petrol or solvent
Fig. 18
10 mm
Fig. 19
Fig. 21