![WHISPER KOOL Quantum SS12000 Owner'S Manual Download Page 30](http://html.mh-extra.com/html/whisper-kool/quantum-ss12000/quantum-ss12000_owners-manual_975190030.webp)
Page 28 | 1-800-343-9463
QS
021616
MAINTENANCE SCHEDULE
Monthly
1. Check for debris surrounding condensing unit(i.e. leaves, branches, trash ect.).
Remove all obstructions.
2. Check for unusual noise or vibration.
3. Check the drain line to see if it is above the waterline if draining into a vessel.
Quarterly 1.
Use a vacuum with brush attachment to clean the evaporator coil. Be careful not to
crush coil fins when cleaning.
2. Ensure the condensing unit is free of debris and dust.
3. Have a certified HVAC Technician service the condensing unit/clean the condenser coil.
4. Check condensate pan for sludge build up and dirty filter in the pump’s reservoir. A
condensate drain pan treatment is highly recommended to prevent scale and sludge
build up.
Annually
1. Inspect for corrosion.
2. Check wiring connections and integrity of cords.
3. Pour a 50/50 bleach solution into the drain line every spring.