![WHISPER KOOL Quantum SS12000 Owner'S Manual Download Page 15](http://html.mh-extra.com/html/whisper-kool/quantum-ss12000/quantum-ss12000_owners-manual_975190015.webp)
www.whisperkool.com | Page 13
Drain Line
The Quantum evaporator accommodates standard 3/4” CPVC Tubing. It is imperative to use proper primer and glue
to ensure there is a water tight seal between the tubing being connected and the fitting on the unit.
A P-trap is required to ensure proper drainage of the condensation. Below is a detailed diagram of
how the P-trap should be constructed to allow for easy cleaning.
Float Switch
The evaporator unit comes equipped with a float switch to monitor the level of condensation in the drip tray. If the
drain line gets obstructed the float switch will stop the operation of the unit and send a BAL alarm to the display. The
unit will not run until this fault is corrected.
Condensation Drain Line
A condensation drain line is used to remove excess condensation from the unit to a proper discharge location. It is
important that the drain line tube is properly connected.
Failure to use the condensation drain line tube will void the warranty on the unit.
WRONG: Drain line is under water.
DRAIN LINE
Connecting the Drain Line
Apply CPVC primer and glue to the female fitting coming from the
unit and the CPVC Tube that will be connected.
Insert the a piece of CPVC tubing into the Female Fitting.
Route Additional CPVC tubing to an appropriate discharge location.
(Tubing is not provided).
To prevent mold from growing, allow the
drain line to hang above the water line.
NOTE: Use a soft tube cleaning brush to clean out the drain
line. Failure to use a soft brush could cause damage
to the drip tray of the unit and void the warranty.
NOTE: The thread fitting is identified in this drawing to
ensure cleaning the drain is as easy as possible.
TO
UNIT
Summary of Contents for Quantum SS12000
Page 20: ...Page 18 1 800 343 9463 QS 021616 QUANTUM SS9000 CONDENSER WIRING DIAGRAM ...
Page 21: ...www whisperkool com Page 19 QUANTUM SS12000 CONDENSER WIRING DIAGRAM ...
Page 31: ...www whisperkool com Page 29 NOTES ...
Page 40: ...QS 021616 WhisperKOOL 1738 E Alpine Ave Stockton CA 95205 1 800 343 9463 www whisperkool com ...