To Remove the Thermal Fuse & Outlet Thermistor
1.
Unplug dryer or disconnect power.
2.
Perform the procedures on page 4-4, “Removing the
Top Panel” and “Removing the Console/UI” prior to
performing the following steps.
3.
Perform the procedures on page 4-6, “Removing the Front
Panel” prior to performing the following steps.
4.
Remove the four (4) 1/4” hex-head screws from the lint
duct as illustrated in Figure 1. Swivel the lint duct down
and remove.
Swivel down and
remove lint duct.
Figure 1
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Failure to do so can result in death or
electrical shock.
Replace all parts and panels before operating.
Removing the Thermal Fuse & Outlet Thermistor
5.
Disconnect the two wire connectors from the thermal
fuse or outlet thermistor terminals (see Figure 2).
6.
Remove the screw(s) from the thermal fuse or outlet
thermistor and remove the component from the blower
housing (see Figure 2).
Thermal Fuse
2 Lt Blue Wires,
1 Screw
Outlet Thermistor
2 Red Wires,
2 Screws
Blower Housing