7
Electrical Requirements
■
A 120 volt, 60 Hz., AC only, 15- or 20-amp, fused electrical
supply is required. A time-delay fuse or circuit breaker is
recommended. It is recommended that a separate circuit
serving only this appliance be provided.
■
This washer is equipped with a power supply cord having a
3 prong grounding plug.
■
To minimize possible shock hazard, the cord must be plugged
into a mating, 3 prong, grounding-type outlet, grounded in
accordance with local codes and ordinances. If a mating
outlet is not available, it is the personal responsibility and
obligation of the customer to have the properly grounded
outlet installed by a qualified electrician.
■
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the
ground path is adequate.
■
Do not ground to a gas pipe.
■
Check with a qualified electrician if you are not sure the
washer is properly grounded.
■
Do not have a fuse in the neutral or ground circuit.
Electrical
S
hock Hazard
Plu
g
into a
g
rounded
3
pron
g
outlet.
Do not remove
g
round pron
g
.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING