78
Connect neutral wire (white or center) (C) of power supply
cord or cable under center terminal block screw (A).
Tighten screw.
Place ends of remaining wires under outer terminal block
screws. Tighten screws and tighten strain relief.
Optional External Ground
for 3-Wire Connection
IMPORTANT:
You must verify with a qualified electrician
that this grounding method is acceptable before connecting.
2.
Connect neutral wire
1.
Prepare to connect neutral wire
3.
Connect remaining wires
Remove center terminal block screw (A) and green external
ground conductor screw (B).
Connect a separate copper ground wire (D) under the green
external ground conductor screw (B) to an adequate ground.
Finally, install terminal block cover and secure with the three
screws. Now, go to “Route Drain Hose.”
4.
Connect external ground wire
B
A
C
A
D
B