32
ELECTRONIC CONTROL SETUP INSTRUCTIONS
Dryer Diagnostic Mode
This mode is entered by depressing COLORS/DELICATES for one
second while in either of the set-up codes 6 xx or 7 xx or with
a diagnostic code present. Diagnostic codes are cleared on
entry and all display segments should flash. If a diagnostic code
persists, it must be corrected before the diagnostic cycle can
be entered.
All Models:
With all segments flashing, the diagnostic cycle is started by
depressing the PERM PRESS button. The cycle consists of
7 minutes of heat and 1 minute of cooldown.
The COTTON/WHITES button will increment the diagnostic
cycle minutes up to 99, then roll over to 2 minutes. The
COLORS/DELICATES button will cancel this cycle and exit
the diagnostic mode.
Dryer Help Mode
Dryer help mode is entered by pressing the COTTON/WHITES
button while in special pricing option 2.XX. In help mode, the
software revision is displayed. The help mode is advanced by
pressing the PERM PRESS button. See Help Mode Submenu
below for the order in which items are displayed. Press the
COTTON/WHITES button at any time to exit help mode.
Help Codes
Help Code
Description
71
Generation 2 debit card
cycle polling message out of
sequence.
74
Generation 2 debit card
remaining balance message
out of sequence.
75
Generation 2 debit card new
card balance message out of
sequence.
88
Invalid messaging state
found in data acquisition
communications comm_
suprv ( ) routine.
Help Mode Submenu
Step
Display
Indication
Explanation
1
1h.XX
Help Code 1, where XX is the help
code number. *
2
2h.XX
Help Code 2, where XX is the help
code number. *
3
3h.XX
Help Code 3, where XX is the help
code number. *
4
1.X##
Error history code 1, where X is
the F or d code, and ## is the code
number. **
5
2.X##
Error history code 2, where X is
the F or d code, and ## is the code
number. **
6
3.X##
Error history code 3, where X is
the F or d code, and ## is the code
number. **
7
4.X##
Error history code 4, where X is
the F or d code, and ## is the code
number. **
8
SC.XX
CCU software revision, where XX is
the software revision number.
9
SU.XX
UI software revision, where XX is
the software number.
10
EU.XX
UI EEPROM revision, where XX is
the EEPROM number.
* To erase the 3 help codes, press COLORS/DELICATES button.
** The Errors displayed in this section are the history errors
that have occurred in the dryer (not necessarily an error
that is in progress). The current error is displayed in the
MANUAL KEY FUNCTION IN DIAGNOSTIC SUB-MODE.
In help mode, other display symbols and elements are mapped
to reflect the state of various inputs and outputs as follows:
All Dryers
*.. . . . . . . . . . . . . . . . .low voltage present (below about 90 VAC)
°(circle above digit) . . . . . . . . . . . . . . . . . . . . . . . . . . . door closed
OR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . motor sensed running
AIR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . heater/gas valve relay on
FLUFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . motor relay on
Summary of Contents for W10184516D
Page 3: ...3 DRYER SAFETY IMPORTANT When discarding or storing your old clothes dryer remove the door ...
Page 61: ...61 NOTES ...
Page 62: ...62 NOTES ...
Page 63: ...63 NOTES ...