22
1. Remove cardboard from beneath dryer. Place a level on top
edges of dryer, checking each side and front. If not level, tip
dryer and adjust feet up or down as shown in Steps 3 and 4,
repeating as necessary.
LEVELING
Leveling your dryer properly reduces excess noise and vibration.
Not Level
LEVEL
Not Level
ELECTRIC DRYER ELECTRICAL CONNECTIONS
3. Connect remaining wires to outer terminal block.
4. Connect a separate copper ground wire from the external
ground conductor to an adequate ground.
Use for direct wire or power supply cord where local codes
do not permit connecting cabinet-ground conductor to
neutral wire.
Connecting Neutral Wire
1. Remove center terminal block screw. Also remove neutral
ground wire by removing external ground conductor screw.
2. Connect neutral wire and neutral wire of power supply cord/
cable to center terminal block.
Connecting 3-Wire Connection: Optional