2
Location Requirements
NOTE: Do not locate microwave oven within 2 ft (61 cm) of any
gas or electric range, cooktop or oven.
Check the location where the microwave oven will be installed.
The location must provide the following:
■
20
³⁄₈
in. x 14
¹⁄₂
in. x 16 in. (51.8 cm x 36.9 cm x 40.7 cm) wood
cabinet or shelf with a solid plywood bottom
■
Support for weight of 100 lbs. (45.4 kg).
■
20
³⁄₈
in. (51.8 cm) wide minimum opening
■
16 in. (40.7 cm) minimum depth
■
Temperature above 50ºF (10ºC) for proper operation
■
Grounded electrical outlet (see “Electrical Requirements”
section) on rear wall of cabinet enclosure
NOTE: There must be at least one wall stud within cabinet
opening.
Product Dimensions
Electrical Requirements
Observe all governing codes and ordinances. A 120-Volt, 60-Hz,
AC-only, 15- or 20-amp fused electrical supply is required. (A
time-delay fuse is recommended.) It is recommended that a
separate circuit serving only this appliance be provided.
1. Location of grounded outlet
2. Opening in cabinet
Min.
14
1
/
2
"
(36.9 cm)
Min 20
3
/
8
" (51.8 cm)
1"
(2.5 cm)
1
3
/
16
"
(3 cm)
Min
16"
(40.7 cm)
2
1
14
¹⁄₂
"
(36.9 cm)
20
³⁄₈
"
(51.8 cm)
16"
(40.7 cm)
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Failure to follow these instructions can result in
death, fire, or electrical shock.
Do not use an extension cord.
Do not use an adapter.
Do not remove ground prong.
GROUNDING INSTRUCTIONS
■
For all cord connected appliances:
The microwave oven must be grounded. In the event
of an electrical short circuit, grounding reduces the
risk of electric shock by providing an escape wire for
the electric current. The microwave oven is equipped
with a cord having a grounding wire with a grounding
plug. The plug must be plugged into an outlet that is
properly installed and grounded.
WARNING:
Improper use of the grounding plug can
result in a risk of electric shock. Consult a qualified
electrician or serviceman if the grounding instructions
are not completely understood, or if doubt exists as to
whether the microwave oven is properly grounded.
■
For a permanently connected appliance:
This appliance must be connected to a grounded,
metallic, permanent wiring system, or an equipment
grounding conductor should be run with the circuit
conductors and connected to the equipment
grounding terminal or lead on the appliance.
Do not use an extension cord. If the power supply cord
is too short, have a qualified electrician or serviceman
install an outlet near the microwave oven.
SAVE THESE INSTRUCTIONS