background image

STACKING KIT COMPONENTS:

Stacking Support Guides(2)

-34001449

Rear Bracket(2)

-34001463

Maytag Flexing Gas Connector(1) -34001465

Screws-Hex Head(4)

-34001382

Screws Phillips-Pan Head(8)

-6006-001174

Washer(4)

Label Warning(1)

-35001251

Maytag Flexing Gas Connector

Screw-Hex Head

Washer

Stacking Support Guide

Screw Phillips-Pan Head

Rear Bracket

Step10 :

Assemble the Rear Brackets to the dryer

as shown above. Note that four screws must be
used to hold the Rear Brackets to the back of the
dryer. Use four(4) Screws-phillips Pan Head(6006-
001174) in the back of the dryer cabinet.Extra
screws are included in the kit for this.
Note: When Rear Brackets are assembled to the
stacked units, attach the Flexing Hose Use
Warning Label(35001251). The label must be
placed as close as possible to the dryer gas
inlet pipe.

Label-W

arning

Step 13:

Stacked Unit is now ready to

be installed. Refer to detailed installa-
tion instructions packed with products.

Step11 :

Before the stacked unit is pushed into the

installed position, the Maytag Flexing Gas
Connector(34001465) must be installed on the dryer
gas inlet pipe. Attach the 90° elbow of the Flexing
Gas Connector to the dryer gas inlet pipe using
proper gas sealing materials, such as Teflon® tape,
etc. Elbow connection must be gas-tight

Step12 :

Connect the other end of the Maytag Flexing

Gas Connector(34001465) to the house-supply outlet
pipe for the dryer, using proper gas sealing materials,
such as Teflon® tape,etc. 

Leak-test both connections

before proceeding further.

Label-W

arning

STOP HERE

Step 9:

Lift and position dryer into the position on the

washer shown.

Step8 : 

Assemble the Rear Brackets to the washer

as shown above.  Use two(2) Screws-Hex
Head(34001382) with washers in each washing
machine top cover tang if there are two holes.
Use one(1) Screw-Hex Head(34001382) with
washer in each top cover tang if there is one hole.

Washer

GAS DRYER STACKING KIT INSTALLATION INSTRUCTIONS 

(MAH6700 washer & MDG6700 dryer only)

MODEL NO: MALGO27AXX

Summary of Contents for MALGO27AXX

Page 1: ...ed immediately upstream of the gas supply connection to the dryer The dryer must be disconnected from the gas supply piping system during any pressure testing of the system The Flexing Gas Connector supplied with this kit must be uesd for this installation In all applications with the dryer stacked on a washer the Maytag Flexing Gas Line Connector p n34001465 must be used Failure to comply may res...

Page 2: ...iled installa tion instructions packed with products Step11 Before the stacked unit is pushed into the installed position the Maytag Flexing Gas Connector 34001465 must be installed on the dryer gas inlet pipe Attach the 90 elbow of the Flexing Gas Connector to the dryer gas inlet pipe using proper gas sealing materials such as Teflon tape etc Elbow connection must be gas tight Step12 Connect the ...

Page 3: ...nal para tubos de 1 8 pulgadas accesible para la conexión del medidor de prueba La secadora debe estar desconectada del sistema de suministro de gas durante las pruebas de presión del sistema Para esta instalación se debe utilizar el conector de tubería de gas flexible suministrado con este kit En todas las aplicaciones en las que la secadora se coloca sobre la lavadora se debe utilizar un conecto...

Page 4: ...decuado para las conexiones de gas tal como la cinta de Teflon etc La conexión del codo debe ser hermética al gas Paso12 Conecte el otro extremo del conector de gas flexible Maytag 34001465 al tubo de salida del suministro del hogar para la secadora utilizando un material sellador adecuado para las conexiones de gas tal como la cinta de Teflon etc Verifique que ambas conexiones no presenten filtra...

Page 5: ...onnexion d alimentation en gaz du sécheur Le sécheur doit être déconnecté du système de canalisation d alimentation en gaz à chaque test de pression du système Le connecteur de gaz flexible fourni avec ce kit doit impérativement être utilisé pour cette installation Dans toutes les applications où un sécheur est empilé sur un lave linge un connecteur de gaz flexible Maytag réf 34001465 doit être ut...

Page 6: ... étanchéité de gaz approprié tel qu une bande de Téflon etc La connexion du coude doit être étanche au gaz Etape 12 Connectez l autre extrémité du connecteur de gaz flexible Maytag 34001465 à la conduite de sortie de la maison pour le sécheur à l aide d un matériau d étanchéité de gaz approprié tel qu une bande de Téflon etc Avant de poursuivre vérifiez que les deux connexions ne présentent pas de...

Reviews: