background image

GAS DRYER STACKING KIT INSTALLATION INSTRUCTIONS 

(MAH6700 washer & MDG6700 dryer only)

GAS REQUIREMENTS

Use only Natural or LP (liquid petroleum) gases.

THE INSTALLATION MUST COMFORM WITH LOCAL CODES, OR IN THE
ABSENCE OF LOCAL CODES, WITH THE NATIONAL FUEL GAS CODE
ANSI/Z223.1, LATEST REVISION (FOR THE UNITED STATES), OR WITH THE
CAN/CGA-B149 INSTALLATION CODES (FOR CANADA).

A gas dryer is equipped with a burner orifice for operation on NATURAL gas. 

If the

dryer is to be operated on LP gas, it must be converted for safe and proper
performance and must be converted by a qualified service technician. 

Gas conversion kits from LP-to-natural or natural-to-LP are available and are to be 
installed by a qualified service technician.

Each dryer will provide an input of 22,000 B.T.U. per hour.

A 1/2 inch gas supply line is recommended and must be reduced to connect to the
3/8 inch gas line on the dryer.

The National Fuel Gas Code requires that an accessible, approved manual gas
shut off valve be installed within 6 feet of the dryer.

Additionally, a 1/8 inch N.P.T. (National Pipe Thread) plugged tapping, accessible
for test gauge connection, must be installed immediately upstream of the gas
supply connection to the dryer.

The dryer must be disconnected from the gas supply piping system during any
pressure testing of the system.

The Flexing Gas Connector supplied with this kit must be uesd for this installation.
In all applications with the dryer stacked on a washer, the Maytag Flexing Gas Line 
Connector(p/n34001465)must be used.
Failure to comply may result in gas line failure or gas leaks.

NOTE 

:

Any pipe joint compound used must be resistant to the action of any

liquified petroleum gas.

GAS IGNITION

-

The dryer uses an automatic ignition system to ignite the burner.

There is no constant burning pilot.

DC68-01052F  REV(0.1)

Step 1:

Place cover (cloth, cardboard, or carpeting) on floor

surface to avoid damage.

Step 2:

Lay the dryer on its side (not front or back).

Step 7:

Bottom view of the dryer after

assembling the Stacking Support Guides to
the dryer base.

Step 3:

Unscrew and disassemble the 

four leg assemblies.

Step 4:

Disassemble each leg from the bracket. 

Then flip the bracket over and remount onto the leg.

Step 5:

Reassemble each leg and bracket

into the dryer base.

Step 6:

Snap the Stacking Support Guides into the

rectangular holes in the dryer base and secure each
with two(2) Screws Phillips-pan head(6006-001174).

Hook

Caution

: Two people are required to lift the dryer on 

to the  washer.   

Dryer

MODEL NO: MALGO27AXX

Summary of Contents for MALGO27AXX

Page 1: ...ed immediately upstream of the gas supply connection to the dryer The dryer must be disconnected from the gas supply piping system during any pressure testing of the system The Flexing Gas Connector supplied with this kit must be uesd for this installation In all applications with the dryer stacked on a washer the Maytag Flexing Gas Line Connector p n34001465 must be used Failure to comply may res...

Page 2: ...iled installa tion instructions packed with products Step11 Before the stacked unit is pushed into the installed position the Maytag Flexing Gas Connector 34001465 must be installed on the dryer gas inlet pipe Attach the 90 elbow of the Flexing Gas Connector to the dryer gas inlet pipe using proper gas sealing materials such as Teflon tape etc Elbow connection must be gas tight Step12 Connect the ...

Page 3: ...nal para tubos de 1 8 pulgadas accesible para la conexión del medidor de prueba La secadora debe estar desconectada del sistema de suministro de gas durante las pruebas de presión del sistema Para esta instalación se debe utilizar el conector de tubería de gas flexible suministrado con este kit En todas las aplicaciones en las que la secadora se coloca sobre la lavadora se debe utilizar un conecto...

Page 4: ...decuado para las conexiones de gas tal como la cinta de Teflon etc La conexión del codo debe ser hermética al gas Paso12 Conecte el otro extremo del conector de gas flexible Maytag 34001465 al tubo de salida del suministro del hogar para la secadora utilizando un material sellador adecuado para las conexiones de gas tal como la cinta de Teflon etc Verifique que ambas conexiones no presenten filtra...

Page 5: ...onnexion d alimentation en gaz du sécheur Le sécheur doit être déconnecté du système de canalisation d alimentation en gaz à chaque test de pression du système Le connecteur de gaz flexible fourni avec ce kit doit impérativement être utilisé pour cette installation Dans toutes les applications où un sécheur est empilé sur un lave linge un connecteur de gaz flexible Maytag réf 34001465 doit être ut...

Page 6: ... étanchéité de gaz approprié tel qu une bande de Téflon etc La connexion du coude doit être étanche au gaz Etape 12 Connectez l autre extrémité du connecteur de gaz flexible Maytag 34001465 à la conduite de sortie de la maison pour le sécheur à l aide d un matériau d étanchéité de gaz approprié tel qu une bande de Téflon etc Avant de poursuivre vérifiez que les deux connexions ne présentent pas de...

Reviews: