background image

6

Make electrical
connection

Electrical Shock Hazard

Disconnect power before making
electrical connections.

Connect ground wire to green
ground screw in terminal box.

Failure to do so can result in
death or electrical shock.

WARNING

22.

Reinstall blower.

Vented installations:

Reinstall blower. 

Do not grasp

blower by blower wheels.

Position

blower so that blower discharge
lines up with damper/vent
connector and slip rods into
mounting brackets on blower
assembly. Tighten knurled nuts
securely and reconnect blower
plug.

Non-vented installations:

19.

Make electrical

connections. Install locknut on
electrical connector and tighten
securely. Connect white to white
and black to black wires using
twist-on connectors. Connect
green or bare ground wire to the
green ground screw.

Using a U.L.-listed power
supply cord-connection kit 
(U.S. only):

Follow Power Cord Kit instructions for
connecting wiring.

20.

Replace wiring box cover

and screws. Make sure that wires
are not pinched between cover
and hood. 

21.

Install two 75 watt max.

bulbs, or one 75 watt and one 25
watt bulb for night-light use. Install
25 watt bulb in right-hand socket.

To get the most efficient

use from your new range

hood, read the “Use and

Care Information” section.

Keep your Whirlpool

Installation Instructions and

Use and Care Guide close

to range hood for easy

reference.

white

green 

green or bare
ground wire

black

black

locknut

electrical
connector

horizontal vent

blower
discharge

front holes

blower
discharge

vertical vent

13.

Lift the range hood up

under cabinet and determine final
position. Mark on the underside
of cabinet the location of the four
keyhole mounting slots. Set
range hood aside on a protected
surface.

keyhole slot

front 
of hood

14.

Use 1/8" (or 3 mm) drill bit

and drill 4 pilot holes as shown.

drill pilot hole

15.

Remove the 4 hood

mounting screws from the parts bag
and install in pilot holes. Leave
screw heads away from filler
strips or cabinet bottom about
1/4" (6.4 cm)

16.

If using direct wiring, make

sure power is disconnected, and pull
about 12" (30 cm) of wire through
wall or cabinet and into opening.

17.

Lift range hood into final

position, feeding electrical wire
through wiring opening. Position the
range hood so that the large end of
the keyhole slots are over the
screws. Then push the hood toward
the wall so that the screws are in the
neck of the slots. Tighten mounting
screws to cabinet, making sure
mounting screws are in narrow neck
of slots. Make sure that damper
blade, if used, rotates up and down
freely.

18.

Connect ventwork to hood.

Seal joints with duct tape to make
the secure and air tight.

1/4" 

(6.4 mm)

blower
discharge

Reinstall blower. 

Do not grasp

blower by blower wheels.

Move

mounting rods to front holes in
hood support channels. Position
blower so that blower discharge
lines up with louvered opening on
hood front. 

Slip rods into mounting brackets
and tighten knurled nuts securely.
Reconnect blower plug. 

Remove louver cover on control
panel. Pry cover off with
screwdriver or knife.

23.

Reinstall bottom cover

(see Step 6).

louver
cover

Summary of Contents for GZ8330 Series and

Page 1: ...erence Save Installation Instructions for local electrical inspector s use 99043793A 9763373 www whirlpool com Quick Reference Table of Contents Pages Before you start Electrical requirements Product dimensions Venting requirements Installation steps Use and Care Information Warranty Requesting Assistance or Service 2 2 3 3 4 4 7 7 8 8 9 10 30 76 2 cm and 36 91 4 cm Convertible Range Hood GZ8330 S...

Page 2: ... and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Ducted fans must always be vented to the outdoors WARNING To reduce the risk of fire use only metal ductwork This unit must be grounded flat blade screwdriver pliers drill ruler 1 1 4 3 0 cm drill bit 1 8 or 3 mm drill bit fo...

Page 3: ...efore installing the hood NOTE If a non vented recirculating installation is desired follow instructions on Page 5 The length of the vent system and number of elbows should be kept to a minimum to provide efficient performance The size of the vent system should be uniform Do Not install two elbows together Use duct tape to seal all joints in the vent system Vent system can terminate either through...

Page 4: ... 5 ft 1 5 m 45 elbow 2 5 ft 0 8 m 3 1 4 x 10 8 3 x 25 4 cm to 6 15 2 cm 90 elbow 5 ft 1 5 m 6 15 2 cm wall cap 0 ft 0 m Slide cardboard or hardboard under range before moving range across floor to prevent damaging floor covering Cover countertop cooktop or set in range with a thick protective covering to prevent damaging them 1 Disconnect and move freestanding range from cabinet opening to provide...

Page 5: ...ting rod mounting bracket blower assembly blower wheel light lens filters screws bottom cover wiring box cover screws For vented installations go to Step 12a For non vented installations go to Step 13 12a Depending on your installation remove either back or top vent knockout 12b Attach the damper vent connector to the hood Use the two black sheet metal screws provided in the parts bag Note If wall...

Page 6: ...zontal vent blower discharge front holes blower discharge vertical vent 13 Lift the range hood up under cabinet and determine final position Mark on the underside of cabinet the location of the four keyhole mounting slots Set range hood aside on a protected surface keyhole slot front of hood 14 Use 1 8 or 3 mm drill bit and drill 4 pilot holes as shown drill pilot hole 15 Remove the 4 hood mountin...

Page 7: ...ch power off at service panel and lock switch power off at service panel and lock service panel to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel CAUTION For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors WARNING TO R...

Page 8: ...you how to use your major appliance to replace or repair house fuses or to correct house wiring or plumbing 2 Service calls to repair or replace appliance light bulbs air filters or water filters Those consumable parts are excluded from warranty coverage 3 Repairs when your major appliance is used for other than normal single family household use 4 Damage resulting from accident alteration misuse ...

Page 9: ... area call our Customer Interaction Center telephone number your nearest authorized service center or Whirlpool Factory Service at 1 800 442 1111 For further assistance If you need further assistance you can write to ask any questions or tell us about your concerns at Customer Interaction Center c o Correspondence Dept 2000 North M 63 Benton Harbor MI 49022 2692 Please include a daytime phone numb...

Page 10: ...n ONTARIO QUEBEC Montreal except South Shore 1 800 361 3032 South Shore Montreal 1 800 361 0950 Quebec City 1 800 463 1523 Sherbrooke 1 800 567 6966 ATLANTIC PROVINCES 1 800 565 1598 For further assistance If you need further assistance you can write to Inglis Limited with any questions or concerns at Consumer Relations Department Inglis Limited 1901 Minnesota Court Mississauga Ontario L5N 3A7 Ple...

Page 11: ...es instructions d installation à l intention de l inspecteur local des installations électriques 99043793A 9763373 www whirlpool com Consultation rapide Table des matières Pages Avant de commencer Spécifications pour l installation électrique Dimensions du produit Circuit de décharge de l air Les étapes de l installation Utilisation et entretien Garantie Demande d assistance ou de service 2 3 3 3 ...

Page 12: ...mm 1 8 po pour les avant trous crayon Matériel nécessaire pour l installation avec décharge à l extérieur compas ou gabarit circulaire de 20 3 cm 8 po cisaille de ferblantier scie à guichet scie sauteuse ruban adhésif pour conduit Pour conduit d évacuation cylindrique raccord de transition 81 3 cm x 25 4 cm 3 1 4 x 10 po à diamètre 15 2 cm 6 po Clapet rond de 15 2 cm 6 po pour un conduit d évacuat...

Page 13: ...ation au dessus d un plafond ou dans autre espace fermé Ne pas utiliser une bouche de décharge murale de 10 2 cm 4 po normalement utilisée pour un équipement de buanderie Ne pas utiliser des conduits de plastique Le système d évacuation nécessaire pour l installation n est pas inclus Déterminer la méthode appropriée pour la décharge à l extérieur On recommande que le conduit de décharge soit insta...

Page 14: ...le plan de travail pour la protection contre les dommages et souillures 3 Si le placard comporte un fond en retrait ajouter une tringle de remplissage de chaque côté Positionner les vis de fixation des tringles aux emplacements indiqués 2 Déterminer quelle méthode de décharge de l air sera utilisée à travers le toit à travers le mur ou sans évacuation Lors de l expédition cette hotte est configuré...

Page 15: ...s excessif Deux personnes ou plus doivent participer aux opérations de manipulation de la hotte Le non respect de cette instruction peut provoquer des blessures du dos ou autres blessures AVERTISSEMENT Pour les éstapes 5 à 10 inclusivement voir la figure 3 5 Placer la hotte à l envers sur un matériau de protection carton ou grande serviette 6 Ôter les vis du couvercle inférieur et le couvercle inf...

Page 16: ...e étroite des trous d accrochage sous les têtes de vis Serrer les vis de montage vérifier que la tête de chaque vis est placée au niveau de la partie étroite du trou d accrochage correspondant Le cas échéant vérifier que le volet de réglage peut pivoter librement dans les deux directions 18 Raccorder le conduit d évacuation à la hotte Assurer l étanchéité à l air des jointures avec du ruban adhési...

Page 17: ... rainures supérieures pousser dans et tirer vers le bas Installation avec recyclage Emboîter le filtre d aluminium à l avant du filtre à charbon Veiller à ce que les pattes du filtre d aluminium soient alignées avec la tirette d extraction du filtre à charbon Pousser l ensemble des filtres dans la rainure supérieure Les rabats du filtre assureront le maintien contre les bords de l ouverture au som...

Page 18: ...disant le rétablissement de l alimentation MISE EN GARDE Cet appareil est conçu uniquement pour la ventilation générale Ne pas l utiliser pour l évacuation de matières ou vapeurs dangereuses ou explosives AVERTISSEMENT POUR MINIMISER LE RISQUE D UN FEU DE GRAISSE SUR LATABLE DE CUISSON Ne pas laisser une cuisson en cours à feu vif sans surveillance Un débordement peut provoquer la génération de fu...

Page 19: ... ou rectifier le câblage ou la plomberie du domicile 2 Les visites de service pour réparer ou remplacer les ampoules électriques de l appareil les filtres à air ou les filtres à eau Ces pièces consomptibles ne sont pas couvertes par la garantie 3 Les réparations lorsque le gros appareil ménager est utilisé à des fins autres que l usage unifamilial normal 4 Les dommages imputables à accident modifi...

Page 20: ...dicatif régional 807 en ONTARIO QUÉBEC Montréal à l exception de la rive sud 1 800 361 3032 Rive Sud Montréal 1 800 361 0950 Québec 1 800 463 1523 Sherbrooke 1 800 567 6966 PROVINCES DE L ATLANTIQUE 1 800 565 1598 Pour plus d assistance Si vous avez besoin d autre d assistance vous pouvez écrire à Inglis Ltée en soumettant toute question ou préoccupation au Service des relations avec la clientèle ...

Reviews: