background image

5

Cabinet Dimensions

IMPORTANT: If installing a range hood or microwave hood 
combination above the cooktop, follow the range hood or 
microwave hood combination installation instructions for 
dimensional clearances above the cooktop surface.

NOTES: After making the countertop cutout, some installations 
may require notching down the base cabinet side walls to clear 
the cooktop base. To avoid this modification, use a base cabinet 
with sidewalls wider than the cutout.

If cabinet has a drawer, a 4" (10.2 cm) depth clearance from the 
countertop to the top of the drawer (or other obstruction) in base 
cabinet is required. The drawer depth may need to be shortened 
to avoid interfering with the regulator.

IMPORTANT: If an undercounter built-in wall oven is to be 
installed below this cooktop, the grounded outlet (H) and gas 
supply piping must be located in an adjacent cabinet.

This cooktop and its gas and electrical supply sources must be 
installed before the undercounter built-in wall oven is installed.

Electrical Requirements

IMPORTANT: The cooktop must be electrically grounded in 
accordance with local codes and ordinances, or in the absence 
of local codes, with the National Electrical Code, ANSI/NFPA 70 
or Canadian Electrical Code, CSA C22.1.

If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrical installer determine that 
the ground path is adequate.

A copy of the above code standards can be obtained from:

National Fire Protection Association

1 Batterymarch Park

Quincy, MA 02169-7471

CSA International

8501 East Pleasant Valley Road

Cleveland, OH 44131-5575

A 120 volt, 60 Hz, AC only, 15-amp, fused electrical circuit is 
required. A time-delay fuse or circuit breaker is also 
recommended. It is recommended that a separate circuit 
serving only this cooktop be provided.

Electronic ignition systems operate within wide voltage limits, 
but proper grounding and polarity are necessary. Check that 
the outlet provides 120-volt power and is correctly grounded. 

The wiring diagrams are provided with this cooktop. See 
“Wiring Diagrams” on a separate sheet. The wiring diagrams 
are located on the left underside of the cooktop base.

A. 30" (76.2 cm) on 30" models; 36" (91.4 cm) on 36" models
B. Combustible area above countertop (shown by dashed 

box above)

C. 30" (76.2 cm) minimum clearance between top of cooktop 

platform and bottom of uncovered wood or metal cabinet 
(24" [61 cm] minimum clearance if bottom of wood or metal 
cabinet is covered by not less than 

¹⁄₄

" [0.6 cm] flame retardant 

millboard covered with not less than No. 28 
MSG sheet steel, 0.015" [0.04 cm] stainless steel, or
0.024" [0.06 cm] aluminum or 0.020" [0.05 cm] copper)

D. 13" (33 cm) recommended upper cabinet depth

E. 3

¹⁄₈

" (7.9 cm)

F. 19" (48.3 cm)

G. 18" (45.7 cm) minimum clearance from upper cabinet to 

countertop within minimum horizontal clearances to cooktop

H. Grounded outlet - Locate within 24" (61 cm) of right rear 

corner of cutout (with no undercounter built-in oven installed 
below cooktop)

I. 29" (73.7 cm) on 30" models; 35¼" (89.5 cm) on 36" models

J. 8

³⁄₈

" (21.3 cm) minimum distance to nearest left and right side 

combustible surface

K. 2

⁷⁄₈

" (7.3 cm) minimum distance to rear combustible surface

L. Gas line opening - Wall: anywhere 5" (12.7 cm) below 

underside of countertop. Cabinet floor: anywhere within
6" (15.2 cm) of rear wall is recommended (with no 
undercounter built-in oven installed below cooktop)

M. 25" (63.5 cm) minimum countertop depth is required

B

D

A

C

E

F

H

I

J

G

K

L

M

J

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.

Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death, 
fire, or electrical shock.

WARNING

Summary of Contents for G7CG3064

Page 1: ...tallation 9 SÉCURITÉ DE LA TABLE DE CUISSON 11 EXIGENCES D INSTALLATION 12 Outillage et pièces 12 Exigences d emplacement 12 Spécifications électriques 14 Spécifications de l alimentation en gaz 15 INSTRUCTIONS D INSTALLATION 16 Installation de la table de cuisson 16 Raccordement au gaz 17 Achever l installation 19 W10526073A IMPORTANT Installer Leave installation instructions with the homeowner H...

Page 2: ...g property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch Do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you can...

Page 3: ... floor where cooktop is to be installed must be sealed Cabinet opening dimensions that are shown must be used Given dimensions are minimum clearances Grounded electrical supply is required See Electrical Requirements section Proper gas supply connection must be available See Gas Supply Requirements section The cooktop is designed to hang from the countertop by its side or rear flanges The gas and ...

Page 4: ...D 28 72 4 cm E 3 8 9 cm F 4 11 7 cm G 11 27 9 cm A 21 54 6 cm B 29 75 0 cm C 18 48 0 cm D 28 72 4 cm E 3 9 3 cm F 4 11 6 cm G 10 27 6 cm G F A E C D B E B G F A C D A 20 53 2 cm B 37 95 4 cm C 18 48 0 cm D 34 87 6 cm E 3 8 9 cm F 4 11 6 cm G 7 19 1 cm A 21 53 3 cm B 36 91 4 cm C 18 48 0 cm D 34 87 6 cm E 3 8 6 cm F 4 11 0 cm G 7 19 1 cm G F C E B D A B G F D A E C ...

Page 5: ...ded It is recommended that a separate circuit serving only this cooktop be provided Electronic ignition systems operate within wide voltage limits but proper grounding and polarity are necessary Check that the outlet provides 120 volt power and is correctly grounded The wiring diagrams are provided with this cooktop See Wiring Diagrams on a separate sheet The wiring diagrams are located on the lef...

Page 6: ...or tubing size should be minimum Usually LP gas suppliers determine the size and materials used in the system Flexible metal appliance connector If local codes permit use a or I D flexible stainless steel tubing gas connector designed by CSA to connect the cooktop to the rigid gas supply line A male pipe thread is needed for connection to the female pipe threads of the inlet to the cooktop pressur...

Page 7: ... The cooktop must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than psi 3 5 kPa INSTALLATION INSTRUCTIONS InstallCooktop Decide on the final location for the cooktop Avoid drilling into or severing existing wiring during installation 1 Determine whether you...

Page 8: ...ap approximately 3 mm between cooktop and countertop A WARNING Explosion Hazard Use a new CSA International approved gas supply line Install a shut off valve Securely tighten all gas connections If connected to LP have a qualified person make sure gas pressure does not exceed 14 36 cm water column Examples of a qualified person include licensed heating personnel authorized gas company personnel an...

Page 9: ...e IGNITE position the system creates a spark to light the burner This sparking continues as long as the control knob is turned to IGNITE Check Operation of Surface Burners Push in and turn the surface burners control knobs to light The surface burner flame should light within 4 seconds The first time a surface burner is lighted it may take longer that 4 seconds to light because of air in the gas l...

Page 10: ...west setting 2 Remove the control knob 3 Hold the knob stem in the low position using a pair of pliers Use an 3 0 mm flat blade screwdriver to turn the screw located in the center of the control knob stem until the flame is the proper size 4 Replace the control knob 5 Test the flame by turning the control from LO to HI checking the flame at each setting 6 Repeat above steps for each burner A Low f...

Page 11: ...n décès Ne pas entreposer ni utiliser de l essence ou d autres vapeurs ou liquides inflammables à proximité de cet appareil ou de tout autre appareil électroménager QUE FAIRE DANS LE CAS D UNE ODEUR DE GAZ Ne pas tenter d allumer un appareil Ne pas toucher à un commutateur électrique Ne pas utiliser le téléphone se trouvant sur les lieux Appeler immédiatement le fournisseur de gaz à partir du télé...

Page 12: ...et pour connaître les dimensions correctes La table de cuisson doit être installée dans un emplacement à l écart des zones de forts courants d air telles que fenêtres portes et évents ou ventilateurs de chauffage puissants Toutes les ouvertures dans le mur ou le plancher de l emplacement d installation de la table de cuisson doivent être scellées Respecter les dimensions indiquées pour la cavité d...

Page 13: ... locaux en vigueur Dimensions du produit Modèle de 30 76 2 cm G7CG3064 Modèle de 30 76 2 cm W5CG3024 Modèle de 36 91 4 cm G7CG3665 Modèle de 36 91 4 cm W5CG3625 Dimensions du placard IMPORTANT En cas d installation d une hotte ou d un ensemble hotte micro ondes au dessus de la table de cuisson suivre les instructions d installation fournies avec la hotte ou l ensemble hotte micro ondes concernant ...

Page 14: ... V et qu elle est correctement reliée à la terre Les schémas de câblage sont fournis avec cette table de cuisson Voir la section Schémas de câblage sur une feuille séparée Les schémas de câblage se trouvent sur la partie inférieure de la base de la table de cuisson du côté gauche A 30 76 2 cm sur les modèles de 30 36 91 4 cm sur les modèles de 36 B Zone de matière combustible au dessus du plan de ...

Page 15: ...iliser et le diamètre approprié Raccord métallique flexible Si les codes locaux le permettent utiliser un connecteur à gaz flexible en acier inoxydable de ou de diamètre interne conçu par CSA pour raccorder la table de cuisson à la canalisation rigide d alimentation en gaz Un raccord avec filetage mâle de est nécessaire pour la connexion sur le raccord à filetage femelle à l entrée du détendeur de...

Page 16: ...on égale ou inférieure à lb po 3 5 kPa on doit isoler la table de cuisson de la canalisation de gaz en fermant son robinet d arrêt manuel individuel INSTRUCTIONS D INSTALLATION Installationdelatabledecuisson Déterminer l emplacement final de la table de cuisson Éviter de percer dans le câblage existant ou de l endommager pendant l installation 1 Déterminer si l installation des placards permet le ...

Page 17: ...de cuisson B Base de la table de cuisson C Vis de fixation de bride de 2 5 1 cm D Bride de fixation dépassant suffisamment de la base de la table de cuisson pour permettre l installation des vis de fixation E Plan de travail A Petit écart d environ 3 mm entre la table de cuisson et le plan de travail A B C D E A AVERTISSEMENT Risque d explosion Utiliser une canalisation neuve d arrivée de gaz appr...

Page 18: ...encoches des chapeaux de brûleur avec les broches dans la base de chaque brûleur Aligner le porte gicleur de la base du brûleur avec l électrode d allumage Un chapeau de brûleur correctement placé doit être horizontal Si le chapeau de brûleur n est pas correctement placé le brûleur de surface ne peut s allumer Placer les grilles de brûleur sur les brûleurs et chapeaux Pas d appareil sous la table ...

Page 19: ...Vérifier que le cordon d alimentation est branché et qu aucun fusible n est grillé ou que le disjoncteur n est pas ouvert Vérifier que chaque robinet d arrêt de gaz est à la position open ouverture Vérifier que les chapeaux de brûleurs sont correctement placés sur la base des brûleurs S assurer à nouveau du bon fonctionnement des brûleurs Si à ce stade un brûleur ne s allume pas contacter le reven...

Page 20: ...W10526073A 2012 Whirlpool Corporation All rights reserved Used under license in Canada Tous droits réservés Utilisée sous licence au Canada 8 12 Printed in U S A Imprimé aux É U ...