Product Dimensions 29" (737 mm) dryer

Product Dimensions 27" (686 mm) dryer

Recessed front view

Closet side view

Minimum Installation Clearances

Additional clearances for wall, door and floor moldings may be required or if
external exhaust elbow is used.

closet

door

Front
View

3" (76 mm)

3" (76 mm)

24 sq. in.
(155 sq. cm)*

48 sq. in.
(310 sq. cm)*

0" (0 mm)

Closet
door

14"
(356 mm)
max.

1" (25 mm)

0" (0 mm)

15"

(381 mm)*

0"
(0 mm)

29" (737 mm)

27-1/4"

(692 mm)

16"

(406 mm)

ELECTRIC

GAS

EXHAUST

4-3/4"

(121 mm)

13"

(330 mm)

1-1/4"

(32 mm)

BACK VIEW

4" (102 mm)

dia.

1"

(25 mm)

non-coin-operated

models:

7-1/8" (181 mm)

coin-operated

models:

7-7/8" (200 mm)

SIDE VIEW

35"

(889 mm)

25-1/2" (648 mm)

27" (686 mm)

37"

(940 mm)

14"

(356 mm)

ELECTRIC

GAS

EXHAUST

LEFT OR
RIGHT SIDE
EXHAUST

4-3/4"

(121 mm)

13"

(330 mm)

1-1/4"

(32 mm)

BACK VIEW

4-1/4"

(108 mm)

6-3/4"

(152 mm)

4" (102 mm)

dia.

1"

(25 mm)

non-coin-operated

models:

7-1/8" (181 mm)

coin-operated

models:

7-7/8" (200 mm)

SIDE VIEW

BOTTOM

EXHAUST

35"

(889 mm)

26-1/2" (673 mm)

29-1/4" (743 mm)

14-1/8"

(359 mm)

7-1/4"

(184 mm)

10-1/4"

(260 mm)

18-3/8"

(467 mm)

*Opening is the minimum for a closet door.

Louvered doors with equivalent air openings are acceptable.

Summary of Contents for CEM2940TQ

Page 1: ...INSTALLATION INSTRUCTIONS COMMERCIAL DRYER Gas 120 Volt 60 Hz or Electric 120 240 Volt 60 Hz Table of Contents 2 8563800B www roper com ...

Page 2: ... WARNING DRYER SAFETY 2 INSTALLATION REQUIREMENTS 4 Tools and Parts 4 Location Requirements 5 Electrical Requirements 6 Gas Supply Requirements 7 Venting Requirements 8 INSTALLATION INSTRUCTIONS GAS DRYER 10 Install Coin Slide and Coin Box 10 Make Gas Connection 10 FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance It i...

Page 3: ...bor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier Clear the room building or area of all occupants IMPORTANT The gas installation must conform with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z22...

Page 4: ...oors with equivalent air openings are acceptable The dryer must be exhausted outdoors No other fuel burning appliance may be installed in the same closet as the dryer INSTALLATION REQUIREMENTS Tools and Parts Gather the required tools and parts before starting installation Read and follow the instructions provided with any tools listed here Tools needed WARNING Explosion Hazard Keep flammable mate...

Page 5: ...EXHAUST 4 3 4 121 mm 13 330 mm 1 1 4 32 mm BACK VIEW 4 102 mm dia 1 25 mm non coin operated models 7 1 8 181 mm coin operated models 7 7 8 200 mm SIDE VIEW 35 889 mm 25 1 2 648 mm 27 686 mm 37 940 mm 14 356 mm ELECTRIC GAS EXHAUST LEFT OR RIGHT SIDE EXHAUST 4 3 4 121 mm 13 330 mm 1 1 4 32 mm BACK VIEW 4 1 4 108 mm 6 3 4 152 mm 4 102 mm dia 1 25 mm non coin operated models 7 1 8 181 mm coin operate...

Page 6: ...ical installer to ensure that the electrical installation is adequate and in conformance with the National Electrical Code ANSI NFPA 70 latest edition and all local codes and ordinances GROUNDING INSTRUCTIONS SAVE THESE INSTRUCTIONS For a grounded cord connected dryer This dryer must be grounded In the event of a malfunction or breakdown grounding will reduce the risk of electric shock by providin...

Page 7: ... MA 02269 The design of this dryer has been certified by CSA International for use at altitudes up to 10 000 feet 3048 m above sea level at the B T U rating indicated on the model serial plate Burner input adjustments are not required when the dryer is operated up to this elevation When installed above 10 000 feet 3048 m a four percent 4 reduction of the burner B T U rating shown on the model seri...

Page 8: ...IMPORTANT Observe all governing codes and ordinances Only rigid or flexible metal duct shall be used for exhausting The dryer vent must not be connected into any gas vent chimney wall ceiling attic crawlspace or a concealed space of a building Do not use an exhaust hood with a magnetic latch Do not install flexible metal vent in enclosed walls ceilings or floors 4 102 mm heavy metal vent and clamp...

Page 9: ...oom Back draft Damper Kits Part No 3391910 are available from your Whirlpool dealer and should be installed in each dryer s vent to prevent exhausted air from returning into the dryers and to keep the exhaust in balance within the main vent Unobstructed air openings are required Each vent should enter the main vent at an angle pointing in the direction of the airflow Vents entering from the opposi...

Page 10: ...vice door Put the coin vault with lock and key in the meter case opening 8 Remove cardboard or hardboard from under dryer WARNING Excessive Weight Hazard Use two or more people to move and install dryer Failure to do so can result in back or other injury Make Gas Connection 1 Remove red cap from gas pipe 2 Connect gas supply to dryer Use pipe joint compound resistant to the action of L P gas for g...

Page 11: ... door of the meter case by lifting it up at the back Install the money accepting device Refer to manufacturer s instructions for proper installation WARNING Excessive Weight Hazard Use two or more people to move and install dryer Failure to do so can result in back or other injury For dryers using coin slides use adapter kit supplied with dryer 7 Replace the meter case service door Put the coin va...

Page 12: ...the power supply cord to the external ground conductor screw Tighten screw 8 Connect the neutral wire white or center of the power supply cord under the center screw of the terminal block Tighten screw 9 Connect the other wires to outer terminal block screws Tighten screws 10 Tighten strain relief screws 11 Insert tab of the terminal block cover into slot of the dryer rear panel Secure cover with ...

Page 13: ...ter terminal block screws Tighten screws 8 Tighten strain relief screws 9 Insert tab of the terminal block cover into slot of the dryer rear panel Secure cover with hold down screw D A C B 5 Remove the center terminal block screw 6 Remove the appliance neutral ground wire from the external ground conductor screw Connect the appliance neutral ground wire and the neutral wire white or center of the ...

Page 14: ... bare ground wire at 5 127 mm Cut 11 2 38 mm from 3 remaining wires Strip insulation back 1 25 mm Shape ends of wires into a hook C B A E D F 5 Remove the center terminal block screw 6 Remove the appliance neutral ground wire from the external ground conductor screw Fasten under center silver colored terminal block screw 7 Connect the ground wire green or bare of the direct wire cable to the exter...

Page 15: ... wire cut green or bare wire even with outer covering Three wire with ground wire green or bare wire cut short Wire is not used Dryer is grounded through neutral conductor to disconnect box 1 25 mm of wires stripped of insulation 3 1 2 89 mm 5 Loosen or remove the center terminal block screw 6 Place the hooked end of the neutral wire white or center of the direct wire cable under the center screw ...

Page 16: ...eek Just dial 1 800 NO BELTS 1 800 662 3587 the call is toll free When you call you will need the dryer model number and serial number Both numbers can be found on the serial rating plate located in the dryer door well You can install the 30 minute or 60 minute timing cam shipped with dryer as follows 1 Unplug dryer or disconnect power 2 Unlock meter case 3 Turn the timing cam by hand until the V ...

Reviews: