Flexible metal appliance connector:

It is recommended that a new flexible stainless steel gas line,
design-certified by CSA International, be used for connecting
the dryer to the gas supply line. (The gas pipe which extends
through the lower rear of the dryer is provided with

3/8

" male

pipe thread.)

Do not kink or damage the flexible stainless steel gas line
when moving the dryer.

Rigid pipe connection:

The rigid pipe connection requires a combination of pipe fittings
to obtain an in-line connection to the dryer.

Must include a shutoff valve:

The supply line must be equipped with a manual shutoff valve
installed within 6 ft. (1.8 m) of dryer in accordance with
National Fuel Gas Code, ANSI Z223.1. This valve should be
located in the same room as the dryer. It should be in a

location that allows ease of opening and closing. Do not block
access to shutoff valve. The valve is for turning on or shutting
off gas to the dryer.

Installed in a confined area:

If the dryer is installed in a confined area such as a bathroom
or closet, provision must be made for enough air for
combustion and ventilation. Check governing codes and

A. Gas supply line
B. Shutoff valve “open” position

C. To dryer

A

B

C

Gas Supply Requirements

IMPORTANT:

Observe all governing codes and ordinances.

This installation must conform with all local codes and
ordinances. In the absence of local codes, installation must
conform with American National Standard, National Fuel Gas
Code ANSI Z223.1/NFPA 54.

A copy of the above code standards can be obtained from:

National Fire Protection Association

One Batterymarch Park, Quincy, MA 02269

The design of this dryer has been certified by CSA International
for use at altitudes up to 10,000 feet (3048 m) above sea level at
the B.T.U. rating indicated on the model/serial plate. Burner input
adjustments are not required when the dryer is operated up to
this elevation.

When installed above 10,000 feet (3048 m), a four percent (4%)
reduction of the burner B.T.U. rating shown on the model/serial
plate is required for each 1,000 foot (305 m) increase in elevation.
For assistance when converting to other gas types and/or
installing above 10,000 feet (3048 m) elevation, contact your local
service company.

Type of Gas

This dryer is equipped for use with natural gas. It is design-
certified by CSA International for L.P. (propane and butane) gases
with appropriate conversion. No attempt shall be made to convert
the dryer from the gas specified on the serial/rating plate for use
with a different gas without consulting the serving gas supplier.
Conversion must be done by a qualified service technician. Gas
conversion kit part numbers are listed on the gas valve burner
base.

Gas Supply Line

Recommended method

Provide a gas supply line of

1/2

" rigid (IPS) pipe to the dryer

location. Pipe joint compounds that resist the action of LP gas
must be used. Do not use TEFLON

®†

tape. With LP gas,

piping or tubing size can be

1/2

" minimum. Usually, LP gas

suppliers determine the size and materials used in the system.

Alternate method

The gas supply may also be connected using

3/8

" approved

copper or aluminum tubing. If the total length of the supply
line is more than 20 feet (6.1 m), larger tubing will be required.
If using natural gas, do not use copper tubing. Pipe joint
compounds that resist the action of LP gas must be used.

†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.

Summary of Contents for CEM2940TQ

Page 1: ...INSTALLATION INSTRUCTIONS COMMERCIAL DRYER Gas 120 Volt 60 Hz or Electric 120 240 Volt 60 Hz Table of Contents 2 8563800B www roper com ...

Page 2: ... WARNING DRYER SAFETY 2 INSTALLATION REQUIREMENTS 4 Tools and Parts 4 Location Requirements 5 Electrical Requirements 6 Gas Supply Requirements 7 Venting Requirements 8 INSTALLATION INSTRUCTIONS GAS DRYER 10 Install Coin Slide and Coin Box 10 Make Gas Connection 10 FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance It i...

Page 3: ...bor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier Clear the room building or area of all occupants IMPORTANT The gas installation must conform with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z22...

Page 4: ...oors with equivalent air openings are acceptable The dryer must be exhausted outdoors No other fuel burning appliance may be installed in the same closet as the dryer INSTALLATION REQUIREMENTS Tools and Parts Gather the required tools and parts before starting installation Read and follow the instructions provided with any tools listed here Tools needed WARNING Explosion Hazard Keep flammable mate...

Page 5: ...EXHAUST 4 3 4 121 mm 13 330 mm 1 1 4 32 mm BACK VIEW 4 102 mm dia 1 25 mm non coin operated models 7 1 8 181 mm coin operated models 7 7 8 200 mm SIDE VIEW 35 889 mm 25 1 2 648 mm 27 686 mm 37 940 mm 14 356 mm ELECTRIC GAS EXHAUST LEFT OR RIGHT SIDE EXHAUST 4 3 4 121 mm 13 330 mm 1 1 4 32 mm BACK VIEW 4 1 4 108 mm 6 3 4 152 mm 4 102 mm dia 1 25 mm non coin operated models 7 1 8 181 mm coin operate...

Page 6: ...ical installer to ensure that the electrical installation is adequate and in conformance with the National Electrical Code ANSI NFPA 70 latest edition and all local codes and ordinances GROUNDING INSTRUCTIONS SAVE THESE INSTRUCTIONS For a grounded cord connected dryer This dryer must be grounded In the event of a malfunction or breakdown grounding will reduce the risk of electric shock by providin...

Page 7: ... MA 02269 The design of this dryer has been certified by CSA International for use at altitudes up to 10 000 feet 3048 m above sea level at the B T U rating indicated on the model serial plate Burner input adjustments are not required when the dryer is operated up to this elevation When installed above 10 000 feet 3048 m a four percent 4 reduction of the burner B T U rating shown on the model seri...

Page 8: ...IMPORTANT Observe all governing codes and ordinances Only rigid or flexible metal duct shall be used for exhausting The dryer vent must not be connected into any gas vent chimney wall ceiling attic crawlspace or a concealed space of a building Do not use an exhaust hood with a magnetic latch Do not install flexible metal vent in enclosed walls ceilings or floors 4 102 mm heavy metal vent and clamp...

Page 9: ...oom Back draft Damper Kits Part No 3391910 are available from your Whirlpool dealer and should be installed in each dryer s vent to prevent exhausted air from returning into the dryers and to keep the exhaust in balance within the main vent Unobstructed air openings are required Each vent should enter the main vent at an angle pointing in the direction of the airflow Vents entering from the opposi...

Page 10: ...vice door Put the coin vault with lock and key in the meter case opening 8 Remove cardboard or hardboard from under dryer WARNING Excessive Weight Hazard Use two or more people to move and install dryer Failure to do so can result in back or other injury Make Gas Connection 1 Remove red cap from gas pipe 2 Connect gas supply to dryer Use pipe joint compound resistant to the action of L P gas for g...

Page 11: ... door of the meter case by lifting it up at the back Install the money accepting device Refer to manufacturer s instructions for proper installation WARNING Excessive Weight Hazard Use two or more people to move and install dryer Failure to do so can result in back or other injury For dryers using coin slides use adapter kit supplied with dryer 7 Replace the meter case service door Put the coin va...

Page 12: ...the power supply cord to the external ground conductor screw Tighten screw 8 Connect the neutral wire white or center of the power supply cord under the center screw of the terminal block Tighten screw 9 Connect the other wires to outer terminal block screws Tighten screws 10 Tighten strain relief screws 11 Insert tab of the terminal block cover into slot of the dryer rear panel Secure cover with ...

Page 13: ...ter terminal block screws Tighten screws 8 Tighten strain relief screws 9 Insert tab of the terminal block cover into slot of the dryer rear panel Secure cover with hold down screw D A C B 5 Remove the center terminal block screw 6 Remove the appliance neutral ground wire from the external ground conductor screw Connect the appliance neutral ground wire and the neutral wire white or center of the ...

Page 14: ... bare ground wire at 5 127 mm Cut 11 2 38 mm from 3 remaining wires Strip insulation back 1 25 mm Shape ends of wires into a hook C B A E D F 5 Remove the center terminal block screw 6 Remove the appliance neutral ground wire from the external ground conductor screw Fasten under center silver colored terminal block screw 7 Connect the ground wire green or bare of the direct wire cable to the exter...

Page 15: ... wire cut green or bare wire even with outer covering Three wire with ground wire green or bare wire cut short Wire is not used Dryer is grounded through neutral conductor to disconnect box 1 25 mm of wires stripped of insulation 3 1 2 89 mm 5 Loosen or remove the center terminal block screw 6 Place the hooked end of the neutral wire white or center of the direct wire cable under the center screw ...

Page 16: ...eek Just dial 1 800 NO BELTS 1 800 662 3587 the call is toll free When you call you will need the dryer model number and serial number Both numbers can be found on the serial rating plate located in the dryer door well You can install the 30 minute or 60 minute timing cam shipped with dryer as follows 1 Unplug dryer or disconnect power 2 Unlock meter case 3 Turn the timing cam by hand until the V ...