![Whirlpool AGS 836 Technical & Service Manual Download Page 9](http://html.mh-extra.com/html/whirlpool/ags-836/ags-836_technical-and-service-manual_434837009.webp)
9
TECHNICAL DATA
MODEL
COOLING
WATER
USAGE
L/HOUR (1)
ICE
PRODUCTION
WATER
USAGE
L/HOUR (1)
TOTAL
WATER
USAGE
L/HOUR (1)
NET
WEIGHT
(KG)
DIMENSIONS
CRATED
X*Y*Z
GROSS
WEIGHT
(KG)
VOLUME
(M
3
)
WHP AGS 836
4
4
36
490x595x765
41
0.22
WHP AGS 837
15
4
19
36
490x595x765
41
0.22
WHP AGS 838
4
4
39
490x595x830
44
0.24
WHP AGS 839
15
4
19
39
490x595x830
44
0.24
WHP AGS 840
5
5
42
490x595x960
46
0.28
WHP AGS 841
25
5
30
42
490x595x960
46
0.28
WHP AGS 842
7
7
48
610x640x960
56
0.37
WHP AGS 843
33
7
40
48
610x640x960
56
0.37
WHP AGS 844
6
6
55
690x640x1080
66
0.47
WHP AGS 845
35
6
41
55
690x640x1080
66
0.47
WHP AGS 846
23
8
60
770x640x1080
74
0.53
WHP AGS 847
45
23
68
60
770x640x1080
74
0.53
WHP AGS 848
11
12
80
940x640x1080
95
0.65
WHP AGS 849
53
11
64
80
940x640x1080
95
0.65
WHP AGS 850
11
11
98
900*650*1200
113
0.702
WHP AGS 851
70
11
81
98
900*650*1200
113
0.702
MODEL
REFRIG.
CHARGE
HIGH PRESSURE
LOW
PRESSURE
TOTAL
CURR.
FUSES
COMPRESSOR
OUTPUT
TOTAL
OUTPUT
MÍNIMUM
MAXIMUM
AVERAGE
(2)
(1)
(2)
(GR)
Kg/cm
2
Psi
Kg/cm
2
Psi
Kg/cm
2
Psi
(A)
(A)
(W)
(W)
WHP AGS 836
260
16
228
17
240
2.5
38
1.5
10
175
220
WHP AGS 837
190
16
228
17
240
2.5
38
1.5
10
175
220
WHP AGS 838
260
16
228
17
240
2.5
38
1.5
10
190
220
WHP AGS 839
190
16
228
17
240
2.5
38
1.5
10
190
220
WHP AGS 840
270
16
228
17
240
2.5
38
1.7
10
190
270
WHP AGS 841
205/195
16
228
17
240
2.5
38
1.7
10
190
270
WHP AGS 842
270
16
228
17
240
2.5
38
2
10
210
300
WHP AGS 843
290
16
228
17
240
2.5
38
2
10
210
300
WHP AGS 844
370/390
16
228
17
240
2.5
38
2.2
10
210
310
WHP AGS 845
370
16
228
17
240
2.5
38
2.2
10
210
310
WHP AGS 846
370/380
16
228
17
240
2.5
38
2.8
10
365
450
WHP AGS 847
360
16
228
17
240
2.5
38
2.8
10
365
450
WHP AGS 848
425
16
228
17
240
2.5
38
3
10
440
500
WHP AGS 849
425
16
228
17
240
2.5
38
3
10
440
500
WHP AGS 850
400
16
228
17
240
2.5
38
6
10
440
1000
WHP AGS 851
340
16
228
17
240
2.5
38
6
10
440
1000
1) Data obtained at room temperature (20°C), water introduced at 15°C; water quality = 500ppm
2) Maximum consumption obtained at room temperature = 43°, according to UNE climate classification Class T
(Tropicalised).
NOTE: Expansion controlled by capillary.