MAINTENANCE AND CLEANING PROCEDURES
WARNING: Unit should always be disconnected during maintenance/cleaning procedures.
Water Condenser
1) Disconnect machine.
2) Close water faucet.
3) Disconnect water entry/exit from condenser.
4) Prepare a solution of 50% phosphoric acid in distilled water.
5) Distribute solution through condenser. (Solution is more effective at 35°-40°C).
WARNING!
DO NOT USE HYDROCHLORIC ACID
Air Condenser
1) Disconnect machine.
2) Close water faucet.
3) Clean condenser using a vacuum cleaner, brush or low pressure air.
Removing scale (lime) from ice production mechanisms
1) Close the water inlet faucet.
2) Remove lid from top of machine by pulling upwards from the rear part of the lid. Some force is required
for this it may be better to prise it open with a flat screwdriver.