6.
Set the front panel aside and locate the oven thermostat.
7.
Locate the LP gas by-pass screw in the bag containing
literature included with the range. One LP gas by-pass screw
is stamped “48”.
8.
Remove the natural gas by-pass screw with a flat blade
screwdriver, turning counterclockwise.
9.
Install the LP gas by-pass screw with a flat blade screwdriver,
turning clockwise.
10.
Locate the LP gas pilot screw in the bag containing literature
included with the range. One LP gas pilot screw is stamped
“15”.
11.
Remove natural gas pilot screw with a flat blade screwdriver,
turning counterclockwise.
12.
Install the LP gas pilot screw with a flat blade screwdriver,
turning clockwise.
13.
Replace the front panel and screw bottom and top fasteners
in place.
14.
Replace the control knobs. Slowly lower the cooktop until it
snaps into position. Close the oven door.
A
A
B
A. Pilot screw
B. By-pass screw
Complete Conversion
1.
Refer to the “Make Gas Connection” section for proper
connection of the range to the gas supply.
2.
Turn the manual shutoff valve in the gas supply line to the
open position.
3.
Refer to the “Check Operation” section for proper burner
ignition, operation, and burner flame adjustments.
IMPORTANT:
You may have to adjust the “LO” setting for
each cooktop burner.
Checking for proper cooktop and oven burner flames is very
important. The small inner cone should have a very distinct
blue flame
¹⁄₄
" to
¹⁄₂
" (6.4 mm to 13 mm) long. The outer cone
is not as distinct as the inner cone. LP gas flames have a
slightly yellow tip.
4.
Close the broiler door and turn the knob to “OFF”.
5.
Refer to the “Complete Installation” section to complete this
procedure.
14
A. Oven thermostat