2.
Open broiler door and remove broiler pan. The gas pressure
regulator is located in the back right hand corner of the broiler
compartment.
IMPORTANT:
Do not remove the gas pressure regulator.
NOTE:
Do not remove the spring beneath the cap.
3.
Remove the cap from the gas pressure regulator using a flat
blade screwdriver.
4.
Turn the cap over so that LP is visible.
5.
Reinstall the cap.
GAS CONVERSIONS
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti-tip bracket to rear range foot.
Reconnect the anti-tip bracket, if the range is moved.
Failure to follow these instructions can result in death
or serious burns to children and adults.
NOTE:
Gas conversions (from natural gas to LP gas or from LP
gas to natural gas) must be done by a qualified person.
B
C
A. Shutoff valve in “closed” position
B. Gas supply line
C. To range
A
A. Gas pressure regulator
A
A. Cap
A
A. Cap
A
To Convert Gas Pressure Regulator
1.
Ensure that the manual shutoff valve is in the closed position.
LP Gas Conversion
12