background image

037-03 - Electric kettles 50 lt

7

Connect the terminal on the lower right-hand side marked
with the international symbol a connector with a nominal
cross section <10 mm

2

. All the appliances installed and the

earth system of the building shall be connected like this.

Connection to waterworks

Water inlet pressure must be between 50 and 300 kPa,
otherwise install a pressure regulator on the line before
the appliance.
Install a cut-off valve for each supply on the line before
the appliance.
Water connections to 10 mm are fitted in the lower part on
the right-hand side of the appliance. 
Make connections according to regulations currently in
force.

Commissioning and testing

Once all the connections have been made, the appliance
and the overall installation must be checked following the
directions given in this manual.
Check in particular:
- that the protective film has been removed from the ex-

ternal surfaces;

- that the lower front panel removed for the electrical con-

nection of the appliance has been fitted back into posi-
tion;

- that connections have been made in accordance with

the requirements and directions indicated in this ma-
nual;

- that all safety requirements in current standards, statu-

tory regulations and directives have been met;

- that the water connections are leak-free;
- that the electrical connection has been performed ac-

cording to standards.

In addition, check that once the appliance has been in-
stalled, the power cord is neither subject to stretch nor in
contact with nor surfaces.
Now proceed to light the appliance as directed in the in-
structions for use.
While the appliance is in use, voltage should not differ
from the nominal voltage more than +/- 10%.
The test report must be completed in full and submitted to
the customer who should then sign in acceptance. With
effect from this moment, the appliance is covered by the
manufacturer’s warranty.

Maintenance of the appliance

Warning! :

All maintenance operations shall only

be performed by a technically qualified service centre!

To ensure correct and safe operation, the appliance must
be inspected and serviced at least once a year only.
Maintenance includes also controlling the components
and tear of pipes, feeding pipes, electrical components
etc.
It is advisable to replace worn components during mainte-
nance operations to avoid the need for other maintenance
calls and unexpected failures.
It is also advisable to apply for a maintenance contract
with the customer.

Possible failures and their elimination

Warning! :

Only technically qualified service

centres can perform the operations described below!
Warning! :

Before  resetting the safety thermo-

stat, it is always necessary to eliminate the problem
causing its activation!

Summary of Contents for AGB 511/WP

Page 1: ...Installation operating and maintenance instructions ELECTRIC KETTLES 50 lt 0037_GB_42 Validity from serial number 92204355 06 2009 AGB 511 WP ...

Page 2: ... and equipotential bonding 6 Connection to waterworks 7 Commissioning and testing page 7 Maintenance of the appliance 7 Possible failures and their elimination 7 Use and cleaning 8 Warnings and hints for user 8 Instructions for use 8 Filling the jacket 8 Switch on start of cooking and switch off 8 Cleaning and care of the appliance 8 Daily cleaning 8 Special procedures in case of long inactivity 8...

Page 3: ...r connection to 10 mm E Electrical connection F Cold water connection to 10 mm 1 Selector 2 Operation light 3 Pressure gauge 4 Cooking vat drainage tap 5 Vat water feed tap 6 Level water jacket 7 Orange warning light 8 Operating thermostat Models and dimensions AGB 511 WP ...

Page 4: ...tric kettles 50 lt 4 A Position OFF B Position MAX Controls Selector switch Operating thermostat 0 Off 1 50 power 2 100 power 3 100 power 0 2 3 1 0 2 3 1 0 2 3 1 0 2 3 1 0 4 0 6 0 80 1 0 0 0 4 0 6 0 8 0 1 0 0 A B ...

Page 5: ...evention regulations very carefully 2 CHARACTERISTICS OF THE APPLIANCES 3 TECHNICAL DATA Model Width A Depth B Height C Vat diameter Vat height Total volume Usable volume Voltage Input Power Power cable Hot water connection Cold water connection Water pressure Pressure mm mm mm mm mm lt lt kW mm mm kPa bar AGB 511 WP 800 700 900 400 450 58 50 400 V 3N 230 V 3 9 5 x 1 5 mm2 4 x 2 5 mm2 10 10 50 300...

Page 6: ...ect conditions In case of visible damage do not con nect the appliance and notify the sales point immediately Remove the PVC protection from the panels Dispose of packaging according to regulations Generally material is divided according to composition and should be delivered to the waste disposal service There are no special instructions regarding distances from other appliances or walls however ...

Page 7: ...at the water connections are leak free that the electrical connection has been performed ac cording to standards In addition check that once the appliance has been in stalled the power cord is neither subject to stretch nor in contact with nor surfaces Now proceed to light the appliance as directed in the in structions for use While the appliance is in use voltage should not differ from the nomina...

Page 8: ...with The appliance has a four position selector to start cooking functions see figure Controls Here is a list of the procedures for a safe and correct use of the appliance Energising the unit Connect the appliance by turning on the main switch in stalled before it Start of cooking Turn the selector from position 0 to one of the heating positions according to cooking requirements Generally cooking ...

Page 9: ...the adhesive label featuring the tech nical specifications applied on the actual pro duct the label also giving the serial number This symbol indicates that the product is classified ac cording to the regulations in force as an item of electrical and electronic equipment and conforms to EU Directive 2002 96 EC WEEE meaning that at the end of its service life it must be treated separately from dome...

Page 10: ...1 P2 P3 P4 2 3 4 1 3 5 2 4 6 R1 1 3 5 2 4 6 L1 L2 L3 mA 1 2 3 4 5 6 PE 230V 3 0 P1 P2 P3 P4 SE 2 3 1 SE mA Line input terminal board TS Safety thermostat C1 Electromagnetic switch L1 Pilot lamp green voltage L2 Pilot lamp yellow TL Thermostat R1 Heating element SE Four position selector switch Rm Relay for min ...

Page 11: ...E TO COPYING OR PRINTING ERRORS DUE TO ITS POLICY OF CONTINUAL PRODUCT IMPRO VEMENT THE MANUFACTURER RESERVES THE RIGHT TO MAKE ANY CHANGES DEEMED NECESSARY THE MANUFACTURER CANNOT BE HELD RESPONSI BLE IF THE INSTRUCTIONS CONTAINED IN THIS MA NUAL ARE NOT OBSERVED WHIRLPOOL EUROPE srl V le Guido Borghi 27 I 21025 Comerio VA ...

Reviews: