background image

037-03 - Electric kettles 50 lt

6

Construction

- Main structure in AISI 430 with 4 adjustable height feet.
- Panels in stainless steel AISI 304, thickness 10-12/10.
- Cooking vat in stainless steel AISI 316, thickness 20/10.
- Chrome-plated brass drainage tap.
- Lid in stainless steel, hinged and spring balanced in all

opening positions.

- Jacket and lining in stainless steel AISI 304, thickness

15-20/10.

- Heating system comprising shielded heating elements

made from “Incoloy-800” alloy with boiler and steam cir-
culation.

- Jacket pressure is controlled by a safety valve set at 0.5

bar; the appliance is equipped with an analogue pres-
sure gauge.

- The cold water connection is 10 mm.
- The hot water connection is 10 mm.
- Safety thermostat to interrupt operation automatically in

case of failures.

- The appliance is equipped with a four-position selector

with three heating functions:

- position “

0

”   Heating not activated 

- position “

1

”   Reduced power 50% 

- position “

2

”   Full power 100%

- position “

3

”   Full power 100%

Laws, technical prescriptions and di-
rectives

When installing the appliance it is necessary to follow and

comply with the following regulations:
- current regulations on the matter;
- any hygienic-sanitary regulations concerning cooking

environments;

- municipal and/or territorial building regulations and fire

prevention prescriptions;

- current accident prevention guidelines;
- electricity board regulations concerning safety;
- the regulations of the electrical power supply company

or agency;

- any other local prescriptions.

Special requirements for the installa-
tion site

- The room in which the appliance is to operate must be

well ventilated.

- In addition, it is good policy to locate the appliance un-

der an extractor hood so that cooking vapours can be
removed rapidly and continuously. 

- Current regulations require the installation of a multiple

pole switch between the appliance and the electrical
power supply; the switch must have a contact gap of
least 3 mm on each pole.

- This appliance requires two water connections: one for

hot and one for cold water. Each line must be fitted with
an on-off valve.

Warning! : 

The electrical isolating switch and the

water shutoff valves must both be located near to the
appliance, within easy reach for the user. 

Positioning

Remove all the packaging and check that the appliance is
in perfect conditions. In case of visible damage, do not con-
nect the appliance and notify the sales point immediately.
Remove the PVC protection from the panels.
Dispose of packaging according to regulations. Generally
material is divided according to composition and should
be delivered to the waste disposal service.
There are no special instructions regarding distances from
other appliances or walls, however it is advisable to main-
tain a sufficient distance to allow any servicing operations
to be performed. In the event the appliance should be in-
stalled in direct contact with inflammable walls, it is advi-
sable to fit suitable heat insulation.
The appliance must stand level. Small differences in level
can be eliminated by screwing or unscrewing the adjusta-
ble feet: A significantly uneven or sloping stance can af-
fect the operation of the appliance adversely.

Installation

Warning! :  Only qualified technicians must perform
the installation, maintenance and test of the appliance.
Warning! :

Before connecting any parts of the ap-

pliance to supplies, make sure that the latter is equiva-
lent the requirements stated in the technical data plate,
if the appliance has been designed for these supplies.

Electrical connections and equipoten-
tial bonding

Warning! :

The  appliance is supplied to operate

according to the power supply indicated on the data
plate. 

As mentioned, the appliance must be connected to the
power supply by way of a multiple pole main isolating swit-
ch and protection device that must be proportioned to the
power of the appliance (1 mA per kW of rated power).
The earthing system must be efficient.
As this appliance is type X equipment (delivery without
power cable and plug), the cable and other hardware nee-
ded to make the connection to the electrical power supply
must be provided by the installer. 
The power cable shall be of the kind described in the pa-
ragraph “Technical data" and shall be resistant to oil.
The power terminal board can be reached by removing
the lower front panel (unloose the screws). The cable fa-
stener is on the lower right-hand side.
The cable must be fed in from beneath the clamp. The in-
dividual wires are then fastened to the corresponding ter-
minals of the terminal board. The earth wire must be lon-
ger than the other wires, so that in the event of the cable
being jerked or the clamp broken, the live wires will di-
sconnect first. Lock the cord fastener.
The appliance must incorporate an equipotential system.

POSITIONING, INSTALLATION AND MAINTENANCE

Summary of Contents for AGB 511/WP

Page 1: ...Installation operating and maintenance instructions ELECTRIC KETTLES 50 lt 0037_GB_42 Validity from serial number 92204355 06 2009 AGB 511 WP ...

Page 2: ... and equipotential bonding 6 Connection to waterworks 7 Commissioning and testing page 7 Maintenance of the appliance 7 Possible failures and their elimination 7 Use and cleaning 8 Warnings and hints for user 8 Instructions for use 8 Filling the jacket 8 Switch on start of cooking and switch off 8 Cleaning and care of the appliance 8 Daily cleaning 8 Special procedures in case of long inactivity 8...

Page 3: ...r connection to 10 mm E Electrical connection F Cold water connection to 10 mm 1 Selector 2 Operation light 3 Pressure gauge 4 Cooking vat drainage tap 5 Vat water feed tap 6 Level water jacket 7 Orange warning light 8 Operating thermostat Models and dimensions AGB 511 WP ...

Page 4: ...tric kettles 50 lt 4 A Position OFF B Position MAX Controls Selector switch Operating thermostat 0 Off 1 50 power 2 100 power 3 100 power 0 2 3 1 0 2 3 1 0 2 3 1 0 2 3 1 0 4 0 6 0 80 1 0 0 0 4 0 6 0 8 0 1 0 0 A B ...

Page 5: ...evention regulations very carefully 2 CHARACTERISTICS OF THE APPLIANCES 3 TECHNICAL DATA Model Width A Depth B Height C Vat diameter Vat height Total volume Usable volume Voltage Input Power Power cable Hot water connection Cold water connection Water pressure Pressure mm mm mm mm mm lt lt kW mm mm kPa bar AGB 511 WP 800 700 900 400 450 58 50 400 V 3N 230 V 3 9 5 x 1 5 mm2 4 x 2 5 mm2 10 10 50 300...

Page 6: ...ect conditions In case of visible damage do not con nect the appliance and notify the sales point immediately Remove the PVC protection from the panels Dispose of packaging according to regulations Generally material is divided according to composition and should be delivered to the waste disposal service There are no special instructions regarding distances from other appliances or walls however ...

Page 7: ...at the water connections are leak free that the electrical connection has been performed ac cording to standards In addition check that once the appliance has been in stalled the power cord is neither subject to stretch nor in contact with nor surfaces Now proceed to light the appliance as directed in the in structions for use While the appliance is in use voltage should not differ from the nomina...

Page 8: ...with The appliance has a four position selector to start cooking functions see figure Controls Here is a list of the procedures for a safe and correct use of the appliance Energising the unit Connect the appliance by turning on the main switch in stalled before it Start of cooking Turn the selector from position 0 to one of the heating positions according to cooking requirements Generally cooking ...

Page 9: ...the adhesive label featuring the tech nical specifications applied on the actual pro duct the label also giving the serial number This symbol indicates that the product is classified ac cording to the regulations in force as an item of electrical and electronic equipment and conforms to EU Directive 2002 96 EC WEEE meaning that at the end of its service life it must be treated separately from dome...

Page 10: ...1 P2 P3 P4 2 3 4 1 3 5 2 4 6 R1 1 3 5 2 4 6 L1 L2 L3 mA 1 2 3 4 5 6 PE 230V 3 0 P1 P2 P3 P4 SE 2 3 1 SE mA Line input terminal board TS Safety thermostat C1 Electromagnetic switch L1 Pilot lamp green voltage L2 Pilot lamp yellow TL Thermostat R1 Heating element SE Four position selector switch Rm Relay for min ...

Page 11: ...E TO COPYING OR PRINTING ERRORS DUE TO ITS POLICY OF CONTINUAL PRODUCT IMPRO VEMENT THE MANUFACTURER RESERVES THE RIGHT TO MAKE ANY CHANGES DEEMED NECESSARY THE MANUFACTURER CANNOT BE HELD RESPONSI BLE IF THE INSTRUCTIONS CONTAINED IN THIS MA NUAL ARE NOT OBSERVED WHIRLPOOL EUROPE srl V le Guido Borghi 27 I 21025 Comerio VA ...

Reviews: