background image

037-03 - Electric kettles 50 lt

2

Models and dimensions

page  

3

General reminders and notes

5

Technical data

5

Construction

6

Laws, technical prescriptions and 

directives

6

Special requirements for the installation 

site

6

Positioning, installation

and maintenance

6

Positioning

6

Installation

6

Electrical connections and equipotential 

bonding

6

Connection to waterworks

7

Commissioning and testing

page  

7

Maintenance of the appliance

7

Possible failures and their elimination

7

Use and cleaning

8

Warnings and hints for user

8

Instructions for use

8

Filling the jacket

8

Switch on, start of cooking and switch off 8

Cleaning and care of the appliance

8

Daily cleaning

8

Special procedures in case of long 

inactivity

8

Special procedures in case of failures

8

How to proceed, if …

9

WEEE Directive

9

Wiring diagrams

10

Warning

11

INDEX

Summary of Contents for AGB 511/WP

Page 1: ...Installation operating and maintenance instructions ELECTRIC KETTLES 50 lt 0037_GB_42 Validity from serial number 92204355 06 2009 AGB 511 WP ...

Page 2: ... and equipotential bonding 6 Connection to waterworks 7 Commissioning and testing page 7 Maintenance of the appliance 7 Possible failures and their elimination 7 Use and cleaning 8 Warnings and hints for user 8 Instructions for use 8 Filling the jacket 8 Switch on start of cooking and switch off 8 Cleaning and care of the appliance 8 Daily cleaning 8 Special procedures in case of long inactivity 8...

Page 3: ...r connection to 10 mm E Electrical connection F Cold water connection to 10 mm 1 Selector 2 Operation light 3 Pressure gauge 4 Cooking vat drainage tap 5 Vat water feed tap 6 Level water jacket 7 Orange warning light 8 Operating thermostat Models and dimensions AGB 511 WP ...

Page 4: ...tric kettles 50 lt 4 A Position OFF B Position MAX Controls Selector switch Operating thermostat 0 Off 1 50 power 2 100 power 3 100 power 0 2 3 1 0 2 3 1 0 2 3 1 0 2 3 1 0 4 0 6 0 80 1 0 0 0 4 0 6 0 8 0 1 0 0 A B ...

Page 5: ...evention regulations very carefully 2 CHARACTERISTICS OF THE APPLIANCES 3 TECHNICAL DATA Model Width A Depth B Height C Vat diameter Vat height Total volume Usable volume Voltage Input Power Power cable Hot water connection Cold water connection Water pressure Pressure mm mm mm mm mm lt lt kW mm mm kPa bar AGB 511 WP 800 700 900 400 450 58 50 400 V 3N 230 V 3 9 5 x 1 5 mm2 4 x 2 5 mm2 10 10 50 300...

Page 6: ...ect conditions In case of visible damage do not con nect the appliance and notify the sales point immediately Remove the PVC protection from the panels Dispose of packaging according to regulations Generally material is divided according to composition and should be delivered to the waste disposal service There are no special instructions regarding distances from other appliances or walls however ...

Page 7: ...at the water connections are leak free that the electrical connection has been performed ac cording to standards In addition check that once the appliance has been in stalled the power cord is neither subject to stretch nor in contact with nor surfaces Now proceed to light the appliance as directed in the in structions for use While the appliance is in use voltage should not differ from the nomina...

Page 8: ...with The appliance has a four position selector to start cooking functions see figure Controls Here is a list of the procedures for a safe and correct use of the appliance Energising the unit Connect the appliance by turning on the main switch in stalled before it Start of cooking Turn the selector from position 0 to one of the heating positions according to cooking requirements Generally cooking ...

Page 9: ...the adhesive label featuring the tech nical specifications applied on the actual pro duct the label also giving the serial number This symbol indicates that the product is classified ac cording to the regulations in force as an item of electrical and electronic equipment and conforms to EU Directive 2002 96 EC WEEE meaning that at the end of its service life it must be treated separately from dome...

Page 10: ...1 P2 P3 P4 2 3 4 1 3 5 2 4 6 R1 1 3 5 2 4 6 L1 L2 L3 mA 1 2 3 4 5 6 PE 230V 3 0 P1 P2 P3 P4 SE 2 3 1 SE mA Line input terminal board TS Safety thermostat C1 Electromagnetic switch L1 Pilot lamp green voltage L2 Pilot lamp yellow TL Thermostat R1 Heating element SE Four position selector switch Rm Relay for min ...

Page 11: ...E TO COPYING OR PRINTING ERRORS DUE TO ITS POLICY OF CONTINUAL PRODUCT IMPRO VEMENT THE MANUFACTURER RESERVES THE RIGHT TO MAKE ANY CHANGES DEEMED NECESSARY THE MANUFACTURER CANNOT BE HELD RESPONSI BLE IF THE INSTRUCTIONS CONTAINED IN THIS MA NUAL ARE NOT OBSERVED WHIRLPOOL EUROPE srl V le Guido Borghi 27 I 21025 Comerio VA ...

Reviews: