3.

Assemble

3/4" U.L.-listed
strain relief (U.L. marking on strain relief)
into the hole below terminal block
opening. Tighten strain relief screws just
enough to hold the two clamp
sections together. Install power supply
cord/cable through the strain relief.

For a grounded, cord-connected
appliance —

GROUNDING INSTRUCTIONS: 

This appliance must be grounded. In
the event of malfunction or
breakdown, grounding will reduce
the risk of electric shock by providing
a path of least resistance for electric
current.

If using a power supply cord, the plug
must be plugged into an appropriate
outlet that is properly installed and
grounded in accordance with all
local codes and ordinances. 

WARNING - Improper connection of
the equipment-grounding conductor
can result in a risk of electric shock.
Check with a qualified electrician or
serviceman if you are in doubt as to
whether the appliance is properly
grounded. Do not modify the plug
provided with the appliance - if it will
not fit the outlet, have a proper outlet
installed by a qualified electrician.

For a permanently connected
appliance —

GROUNDING INSTRUCTIONS: 

This appliance must be connected to
a grounded metal, permanent wiring
system; or an equipment-grounding
conductor must be run with the
circuit conductors and connected to
the equipment-grounding terminal or
lead on the appliance.

For a grounded, cord-connected
appliance —

GROUNDING INSTRUCTIONS: 

This appliance must be grounded. In
the event of malfunction or
breakdown, grounding will reduce
the risk of electric shock by providing
a path of least resistance for electric
current.

This appliance is equipped with a
cord having an equipment-grounding
conductor and a grounding plug. The
plug must be plugged into an
appropriate outlet that is properly
installed and grounded in
accordance with all local codes and
ordinances. 

Complete installation following
instructions for your type of
connection:

• Four-wire (recommended method)

• Three-wire (if four-wire is not

available)

1.

Disconnect the power supply.

2.

Remove hold-down screw

and terminal block cover.

Power supply cord

(U.S. only)

Direct wire 

(U.S. only)

This dryer is manufactured with the
cabinet-ground conductor
connected to the NEUTRAL (center) of
the wiring harness at the terminal
block. If local codes do NOT permit
this type of connection, use “Four-
wire connection” instructions.

dryer
cabinet

strain relief
screws

strain
relief 
clamp
sections

terminal
block
cover

hold-
down
screw

tab

external ground
conductor screw

Fire Hazard

Use a new UL approved 30
ampere power supply cord.

Use a UL approved strain relief.

Disconnect power before making
electrical connections.

Connect neutral wire (white or
center wire) to center terminal
(silver).

Ground wire (green or bare wire)
must be connected to green
ground connector.

Connect remaining 2 supply
wires to remaining 2 terminals
(gold).

Securely tighten all electrical
connections.

Failure to do so can result in
death, fire, or electrical shock.

Fire Hazard

Use 10 gauge solid copper wire.

Use a UL approved strain relief.

Disconnect power before making
electrical connections.

Connect neutral wire (white or
center wire) to center terminal
(silver).

Ground wire (green or bare wire)
must be connected to green
ground connector.

Connect remaining 2 supply
wires to remaining 2 terminals
(gold).

Securely tighten all electrical
connections.

Failure to do so can result in
death, fire, or electrical shock.

WARNING

WARNING

7.

U.S. installations:

Make electrical connection. 

Canadian installations:

Use a new UL-approved power supply
cord rated 240-volt min., 30 amperes
and marked for use with a clothes
dryer.

WARNING - Improper connection of
the equipment-grounding conductor
can result in a risk of electric shock.
Check with a qualified electrician or
service representative or personnel if
you are in doubt as to whether the
appliance is properly grounded. Do
not modify the plug provided with the
appliance - if it will not fit the outlet,
have a proper outlet installed by a
qualified electrician.

Summary of Contents for 8316558

Page 1: ...nstallation Instructions with the owner Owner Keep Installation Instructions for future reference Save Installation Instructions for local electrical inspector s use COMMERCIAL DRYER GAS Part No 8316558 Rev A COMMERCIAL LAUNDRY PRODUCTS www whirlpool com 120 volt 60 Hz ELECTRIC 120 240 volt 60 Hz ...

Page 2: ...installed in an area where it will be exposed to water and or weather It is your responsibility to If installing a GAS dryer FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliances IMPORTANT SAFETY INSTRUCTIONS WARNING To reduce the risk of fire electric shock or injury to persons when using your appliance follow basic prec...

Page 3: ...hat V shaped notch clears the ratchet tooth 7 Close and lock the meter case Exhaust requirements Do not use non metal flexible vent metal vent that is smaller than four inches in diameter or exhaust hoods with magnetic latches The dryer must be exhausted outdoors Do not exhaust dryer into a gas vent chimney wall ceiling or concealed space of a building Do not install flexible vent in enclosed wall...

Page 4: ...st system is required A main exhaust vent can be used for exhausting a group of dryers Main exhaust vent should be sized to remove 200 CFM of air per dryer Large capacity lint screens of proper design may be used in the main exhaust vent if checked and cleaned frequently The room where the dryers are located should have make up air equal to or greater than the CFM of all the dryers in the room Bac...

Page 5: ...se F The supply line shall be equipped with a shutoff valve installed within 6 ft 1 8 m of dryer in accordance with the National Fuel Gas Code ANSI Z223 1 latest edition In Canada an individual manual shutoff valve must be installed in accordance with the B149 installation codes CAN CGA B149 1 and CAN CGA B149 2 This valve should be located in the same room as the dryer and should be in a location...

Page 6: ...aust hood 12 Carefully move dryer into final position Place level on top of the dryer first side to side then front to back If the dryer is not level adjust the legs of the dryer up or down until the dryer is level 13 Plug power supply cord into grounded outlet 14 Check dryer operation some accumulated time may be on the timer due to factory testing Insert coins in slide and press slide in slowly ...

Page 7: ...a separate ground wire is used it is recommended that a qualified electrician determine that the ground path is adequate Important Observe all governing codes and ordinances A four wire or three wire Canada four wire only single phase 120 240 volt 60 Hz AC only electrical supply or four wire or three wire 120 208 volt if specified on the model serial rating plate is required on a separate 30 amper...

Page 8: ...r type of connection Four wire recommended method Three wire if four wire is not available 1 Disconnect the power supply 2 Remove hold down screw and terminal block cover Power supply cord U S only Direct wire U S only This dryer is manufactured with the cabinet ground conductor connected to the NEUTRAL center of the wiring harness at the terminal block If local codes do NOT permit this type of co...

Page 9: ... other wires to outer terminal block screws Tighten screws 6 Connect the ground wire bare of the power supply cable to the external ground conductor screw Tighten screw 9 Tighten strain relief screws 10 Insert tab of terminal block cover into slot of dryer rear panel Secure cover with hold down screw 9 Tighten strain relief screws 10 Insert tab of terminal block cover into slot of the dryer rear p...

Page 10: ...al wire 4 Loosen or remove center terminal block screw 7 Tighten strain relief screws 8 Insert tab of terminal block cover into slot of dryer rear panel Secure cover with hold down screw 6 Place the hooked ends of the other power supply cable wires under the outer terminal block screws hook facing right Squeeze hooked ends together Tighten screws 5 Place the hooked end of the neutral wire white or...

Page 11: ...nded that a qualified electrician determine that the ground path is adequate 8 To exhaust dryer see Exhaust requirements Pages 3 4 Connect exhaust vent to dryer exhaust outlet and exhaust hood using 4 10 2 cm clamps Use caulking to seal exterior wall opening around exhaust hood 9 Carefully move dryer into final position Place level on top of the dryer first side to side then front to back If the d...

Page 12: ... Recessed front view Closet side view Closet front view 3 7 6 cm 48 sq 24 sq The dryer must be exhausted outdoors No other fuel burning appliance may be installed in the same closet Minimum Installation Clearances 14 35 6 cm max 1 2 5 cm This dryer may be installed in a recessed area or closet For recessed area and closet installations minimum clearances can be found on the serial tag on the dryer...

Page 13: ... 18 3 8 46 7 cm 4 10 2 cm dia 1 2 5 cm non coin operated models 7 1 8 18 1 cm coin operated models 7 7 8 20 cm SIDE VIEW 35 88 9 cm 25 1 2 64 8 cm 27 68 6 cm 37 94 cm 14 35 6 cm ELECTRIC GAS EXHAUST LEFT OR RIGHT SIDE EXHAUST 4 3 4 12 1 cm 13 33 cm 1 1 4 3 2 cm BACK VIEW 4 1 4 10 8 cm 6 3 4 15 2 cm 4 10 2 cm dia 1 2 5 cm non coin operated models 7 1 8 18 1 cm coin operated models 7 7 8 20 cm SIDE ...

Page 14: ...taire Propriétaire Conserver les instructions d installation pour consultation ultérieure Conserver les instructions d installation pour consultation par l inspecteur local des installations électriques SÉCHEUSE COMMERCIALE GAZ Pièce n 8316558 Rév A APPAREILS DE BUANDERIE COMMERCIALE www whirlpool com 120 volts 60 Hz ÉLECTRIQUE 120 240 volts 60 Hz ...

Page 15: ...t aucun risque d exposition aux substances dangereuses générées par la combustion des gaz Remarque La sécheuse ne doit pas être installée en un endroit où elle serait exposée à de l eau ou aux intempéries C est au propriétaire de l appareil qu incombe la responsabilité de Pour l installation d une sécheuse à GAZ INSTRUCTIONS DE SÉCURITÉ IMPORTANTES Avertissement Pour réduire le risque d incendie c...

Page 16: ...duit métallique de diamètre inférieur à 10 2 cm 4 po ou une bouche de décharge avec clapet à fermeture magnétique L orifice d évacuation de la sécheuse doit être relié à l extérieur Ne pas connecter le circuit d évacuation à une cheminée au conduit d évacuation d un appareil à gaz ou à grenier ou vide sanitaire ou à une cavité fermée dissimulée du bâtiment plafond mur etc Ne pas installer un condu...

Page 17: ...nt pour évacuer 94 4 litres sec 200 pi3 m d air par sécheuse Des filtres à charpie de forte capacité et de conception adéquate peuvent être utilisés dans le conduit collectif d évacuation s ils sont inspectés et nettoyés fréquemment La pièce où se trouvent les sécheuses devrait recevoir un apport d air de débit égal ou supérieur au débit total pi3 s de toutes les sécheuses installées dans la pièce...

Page 18: ...se conformément aux prescriptions de la dernière édition de la norme ANSI Z223 1 National Fuel Gas Code Au Canada un robinet d arrêt manuel individuel doit être installé conformément aux prescriptions des normes CAN CGA B149 1 et B149 2 codes d installation Ce robinet doit être situé dans la même pièce que la sécheuse à un endroit où on peut facilement l ouvrir et le fermer Ne pas entraver l accès...

Page 19: ...rmé Si c est nécessaire enlever le panneau de plinthe utiliser un couteau à mastic pour appuyer sur le verrou situé au centre au sommet du panneau de plinthe Tirer vers le bas pour provoquer l ouverture du panneau de plinthe Le panneau de plinthe est monté sur des charnières en bas 9 Ouvrir le robinet d arrêt de la canalisation d arrivée de gaz 10 Utiliser un liquide non corrosif de détection des ...

Page 20: ...és ou de disjoncteurs Méthode recommandée de liaison à la terre Aux É U C est au client qu incombent l obligation et la responsabilité personnelle de contacter un électricien qualifié qui devra vérifier que l installation électrique est adéquate et conforme aux prescriptions du Code national de l électricité ANSI NFPA 70 dernière édition et de tous les codes et règlements locaux Au Canada C est au...

Page 21: ...accordé par un cordon d alimentation INSTRUCTIONS DE LIAISON À LA TERRE Cet appareil doit être relié à la terre Advenant un fonctionnement défectueux ou une panne la liaison à la terre réduira le risque de choc électrique en fournissant une voie de passage de moindre résistance pour le courant électrique Le cordon d alimentation doit être branché dans une prise de courant murale de configuration c...

Page 22: ...e du panneau arrière de la sécheuse Immobiliser le couvercle avec la vis de retenue 4 Ôter la vis de la borne centrale du bloc 5 Séparer le conducteur de liaison à la terre de l appareil vert avec rayure jaune de la vis de connexion au châssis Connecter ce conducteur sous la vis centrale de teinte argent du bloc de connexion 6 Connecter le conducteur vert de liaison à la terre du cordon d alimenta...

Page 23: ...mentation sous la vis de la borne centrale crochet orienté vers la droite Serrer le crochet sur la vis puis serrer la vis 6 Placer l extrémité en crochet des autres conducteurs d alimentation sous les vis des bornes du bloc de connexion crochet orienté vers la droite Serrer le crochet sur la vis puis serrer la vis 7 Serrer les vis du serre câble 8 Insérer l onglet du couvercle du bloc de connexion...

Page 24: ...charge extérieure 9 Placer prudemment la sécheuse à son emplacement final Placer un niveau sur le sommet de la sécheuse transversalement puis dans le sens avant arrière Si la sécheuse n est pas d aplomb ajuster les pieds pour modifier la hauteur et établir un bon aplomb de la sécheuse 10 Aux États Unis et au Canada brancher le cordon d alimentation électrique sur une prise de courant reliée à la t...

Page 25: ...en pouces il s agit des distances minimales Il est utile de prévoir des distances de séparation supérieures pour faciliter l installation et les travaux d entretien ou si ceci est exigé par les codes et règlements locaux Si la porte du placard est installée on doit respecter la taille minimale des ouvertures d entrée d air au sommet et en bas On peut utiliser une porte à jalousies offrant une surf...

Page 26: ...4 cm 37 po 35 6 cm 14 po BOUCHE DE DÉCHARGE CÔTÉ GAUCHE OU CÔTÉ DROIT 12 1 cm 4 3 4 po 33 cm 13 po 3 2 cm 1 1 4 po 10 8 cm 4 1 4 po 15 2 cm 6 3 4 po 10 2 cm 4 po dia 2 5 cm 1 po Modèle sans mécanisme de commande à pièces 18 1 cm 7 1 8 po Modèles avec mécanisme de commande à pièces 20 cm 7 7 8 po Modèle sans mécanisme de commande à pièces 18 1 cm 7 1 8 po Modèles avec mécanisme de commande à pièces...

Reviews: