TECH SHEET - DO NOT DISCARD

PAGE 6

FOR SERVICE TECHNICIAN'S USE ONLY

PART NO. 3979119

120 VOLTS

WHITE - NEUTRAL N

BLACK

L1 LINE -

DOOR

SWITCH

DRIVE MOTOR

4M

MAIN

2.4-3.6
START

2.4-3.8

5M

6M

EVEN HEAT CONTROL

TIMER

DOOR

TIMER

P2-6

PTS

MOTOR

RELAY

P2-7 MOTOR

START

3M

START

SENSE

P1-5

D

D2

D1

BLUE

BK

BU

BLUE

BU

BLUE

BLUE

BELT

SWITCH

WHITE

PK/BK

BLK

BLK

BU

BU/BK

COM

NO

MTR

BLACK PT-1

P1-1

BU

CENTRIFUGAL

SWITCH

HEATER

LOW

P3-2

PK/BK

WHITE

BLUE

MOTOR STRIP CIRCUIT

120 VOLTS

FS2

FS1

VALVE

NO.1

IG

IGR

IGNITOR

50-500

HOLD

ASSIST

MAIN

22,000 BTU/HR

VALVE

NO.2

4

1

3

2

5

FLAME

SENSOR

BLACK

L1 LINE -

WHITE - NEUTRAL N

DOOR

SWITCH

RED/WHITE

5M

6M

THERMISTOR

RED

THERMAL FUSE

196 °F

HIGH LIMIT

THERMOSTAT

205 °F

TEMP.

NEUTRAL

P2-3

P2-1

NC

3M

D

D2

D1

RED

WHITE

WHITE

WHITE/RED

W/R

3V

BLUE

1V

HS1

HS2

TF1

TF2

EVEN HEAT CONTROL

HEATER

RELAY

P3-2

HEATER

HI

P3-1

HEATER

LOW

RED

COM

NO

R/W

R/W

BLUE

CENTRIFUGAL

SWITCH

HEATER STRIP CIRCUIT

BLACK

L1 LINE -

WHITE

N

- NEUTRAL

EVEN HEAT CONTROL

NEUTRAL

TERMINAL

LINKED TO

CABINET

MOIST

GND

MOIST.

NEUTRAL

P2-5

SENSOR

P2-4

P2-1

BK

Y/R

WHITE/RED

G/Y

G/Y

W

MTR

P1-1

BU

TIMER

PT-1

TIMER

BLACK

BU

120 VOLTS

MOISTURE SENSOR STRIP CIRCUIT

MANUFACTURED UNDER ONE OR

MORE OF THE FOLLOWING U.S. PATENTS:

4,385,452

4,430,809

4,663,861

4,669,200

4,700,495

4,720,925

4,754,556

4,821,535

4,840,285

4,865,366

4,899,264

4,899,464

4,908,959

5,066,050

5,243,771

5,560,120

5,636,453

5,651,188

5,664,339

D314,261

D314,262

Summary of Contents for 72972

Page 1: ...ouble beep pause triple beep will sound to indicate that the factory test mode is activated NOTE If any of these initial conditions are not satisfied the control will not enter the test mode Test Mode Functionality When the control is in the Factory Test mode every input change of state will result in a beep with the exception of the Signal switch This includes Door switch Moisture Sensor short op...

Page 2: ...ed temperature Procedure Begin with an empty dryer and a clean lint screen 1 Set the following configuration Timer Dial TIMED DRY Fabric Care Temperature switch COTTON TOWELS HIGH Wrinkle Guard switch OFF Signal switch HIGH Door must be closed 2 Press the Push To Start PTS switch a If you hear three short beeps and the dryer shuts off after several seconds the thermistor or wire harness is either ...

Page 3: ...lacing the thermistor the voltage is still 0VDC at the P3 1 to P3 2 terminals replace the Even Heat Control Assembly PROBLEM Dryer Heats During Air Fluff No Heat Cycle Refer to Heater Strip Circuit page 6 If the dryer heats when the Fabric Care Tem perature switch is set to AIR FLUFF No Heat check the following HARNESS CONNECTION HEATER RELAY FABRIC CARE SWITCH EVEN HEAT CONTROL IMPORTANT Electros...

Page 4: ...5152 3405152 Fabric Care Temperature Switch 3399643 3399643 3399643 Motor Relay 3405281 3405281 3405281 Heater Relay 3405281 3405281 3405281 Even Heat Control Assembly 3976627 3976627 3976627 Timer Knob and Skirt 3402598 3402597 3402595 Console Harness 3976590 3976590 3976590 Main Harness 8299935 8299935 8299935 Door Switch 3392266 3392266 3392266 Thermal Fuse 3390719 3390719 3390719 Gas Burner As...

Page 5: ...ER HI P3 1 HEATER LOW RED COM NO R W R W LOUD BLUE P2 7 BLUE PK BK PTS MOTOR RELAY PK BK BU BLK BU BLK COM NO MOTOR START START SENSE BU BK P1 5 RED WHITE RED CENTRIFUGAL SWITCH P4 5 P4 4 WET W R P4 8 DAMP BLK P4 6 COOL DOWN W BL P4 7 W V P4 3 P4 2 P4 1 BLK BLK L1_ RETURN W R WH BLUE Gas Dryer Wiring Diagram IMPORTANT Electrostatic static electricity discharge may cause damage to electronic contro...

Page 6: ... SWITCH RED WHITE 5M 6M THERMISTOR RED THERMAL FUSE 196 F HIGH LIMIT THERMOSTAT 205 F TEMP NEUTRAL P2 3 P2 1 NC 3M D D2 D1 RED WHITE WHITE WHITE RED W R 3V BLUE 1V HS1 HS2 TF1 TF2 EVEN HEAT CONTROL HEATER RELAY P3 2 HEATER HI P3 1 HEATER LOW RED COM NO R W R W BLUE CENTRIFUGAL SWITCH HEATER STRIP CIRCUIT BLACK L1 LINE WHITE N NEUTRAL EVEN HEAT CONTROL NEUTRAL TERMINAL LINKED TO CABINET MOIST GND M...

Reviews: