TECH SHEET - DO NOT DISCARD

PAGE 4

FOR SERVICE TECHNICIAN'S USE ONLY

PART NO. 3979119

a.

If there is continuity to Ground for

Yellow/Red (Y/R) wire with no

load, look for a short in the Sen-

sor or Y/R wire. Verify harness

connections both at the Sensor

and the Even Heat control.

b.

If the Sensor and Y/R wire are

good, replace the Even Heat

Control Assembly.

2.

If Factory Test is passed, verify

thermistor by performing test proce-

dures outlined in “Thermistor Test”.

3.

If problem persists after replacing

Moisture Sensor and thermistor,

replace the Even Heat Control

Assembly.

PROBLEM: Timer

Continuously Advances

(Refer to Timer Drawing, page 5,
and Motor Strip Circuit, page 6)

If the dryer continues to advance past

the OFF position, check the following:

–  HARNESS/CONNECTION
–  TIMER

IMPORTANT:

Electrostatic (static

electricity) discharge may cause

damage to electronic control assem-

blies. See page 1 for details.

Procedure:

1.

Verify the Blue wire and the Black L1

wires are in the correct positions:

The Black wire goes next to the Red

wire, and the Blue wire is located on

the three terminals that are close to

each other.

2.

Test the Timer by following the proce-

dure outlined in “Factory Test”, be-

ginning on page 1.

3.

If the Timer continues to advance

past OFF, then replace the Timer.

COMPONENT

PART NUMBER

MODEL NO.

72972

72982

72992

(White)

MODEL NO.

72974

72994

(Bisque)

MODEL NO.

72996

(Graphite)

Console Panel

for

White

Models:

72972

72982

72992

8528013

8528014

8528015

for

Bisque

Models:

72974

72994

3979177

8528016

For

Graphite

Model:

72996

3979156

End Cap - R. H.

3949274

3949278

3949277

End Cap Trim - R. H.

3951009

3977759

3953667

End Cap - L. H.

3949280

3949284

3949283

End Cap Trim - L. H.

3951013

3977760

3953668

P.T.S. Switch

3977456

3977456

3977456

P.T.S. Knob *

3402570

3402569

3402567

Control Knob *

3402576 (3) 3402575 (3) 3402573 (3)

Signal Switch

3405151

3405151

3405151

Wrinkle Guard Switch

3405152

3405152

3405152

Fabric Care/Temperature

Switch

3399643

3399643

3399643

Motor Relay

3405281

3405281

3405281

Heater Relay

3405281

3405281

3405281

Even Heat Control Assembly

3976627

3976627

3976627

Timer Knob and Skirt *

3402598

3402597

3402595

Console Harness *

3976590

3976590

3976590

Main Harness *

8299935

8299935

8299935

Door Switch *

3392266

3392266

3392266

Thermal Fuse *

3390719

3390719

3390719

Gas Burner Assembly *

8318276

8318276

8318276

High Limit Thermostat *

3390291

3390291

3390291

Drive Motor *

3395654

3395654

3395654

Thermistor - NTC 10K Ohms *

3976615

3976615

3976615

Timer

3976585

3976585

3976585

Moisture Monitor Light

Assembly *

3976610

3976610

3976610

* not shown

3390646

Ground Screw

Console

Panel

3388228 (2)

Motor Relay

Screws

R.H.

End Cap

Trim

R.H.

End Cap

3390646 (2)

End Cap

Screws

Push To Start

(PTS)

Switch

Signal

Switch

FabricCare/

Temp Switch

3388228 (2)

Heater Relay

Screws

Heater

Relay

Even Heat

Control Asm

(Includes 2 Retainers)

Timer

L.H.

End Cap

Trim

L.H.

End Cap

3390646 (2)

Timer Screws

Control Bracket

Ground Wire

in Main Harness

Motor

Relay

Control

Bracket

Moisture

Monitor

B

B

B

R

U

K

K

W

V

NC

NO

CO

M

Wrinkle

Guard

Switch

Component Location

Moisture Monitor Lights

The Moisture Monitor Lights give an indi-

cation of which stage the dryer is in.
To test the lights, begin the factory test

procedure described on page 1. In fac-

tory test mode, touching or removing a

moist towel or finger on the moisture

strips will cause the lights to single step
through each stage (Wet

Damp

Cool Down

Off

Wet, etc.).

PROBLEMS:

A Moisture Monitor Light

Does Not Come On

1.

If a light does not come on, then

check the terminals in the PS-04 con-

nector on the Even Heat control.

2.

Replace the Moisture Light assembly

(3976610)

3.

Replace the Even Heat control

assembly.

A Moisture Monitor Light

Stays On All the Time

1.

Check the terminals in the PS-04

connector on the Even Heat control.

2.

Replace the Even Heat control

assembly.

All the Moisture Monitor

Lights Stay On or Off

1.

Check the terminals in the PS-04

connector on the Even Heat control.

2.

Replace the Even Heat control

assembly.

Summary of Contents for 72972

Page 1: ...ouble beep pause triple beep will sound to indicate that the factory test mode is activated NOTE If any of these initial conditions are not satisfied the control will not enter the test mode Test Mode Functionality When the control is in the Factory Test mode every input change of state will result in a beep with the exception of the Signal switch This includes Door switch Moisture Sensor short op...

Page 2: ...ed temperature Procedure Begin with an empty dryer and a clean lint screen 1 Set the following configuration Timer Dial TIMED DRY Fabric Care Temperature switch COTTON TOWELS HIGH Wrinkle Guard switch OFF Signal switch HIGH Door must be closed 2 Press the Push To Start PTS switch a If you hear three short beeps and the dryer shuts off after several seconds the thermistor or wire harness is either ...

Page 3: ...lacing the thermistor the voltage is still 0VDC at the P3 1 to P3 2 terminals replace the Even Heat Control Assembly PROBLEM Dryer Heats During Air Fluff No Heat Cycle Refer to Heater Strip Circuit page 6 If the dryer heats when the Fabric Care Tem perature switch is set to AIR FLUFF No Heat check the following HARNESS CONNECTION HEATER RELAY FABRIC CARE SWITCH EVEN HEAT CONTROL IMPORTANT Electros...

Page 4: ...5152 3405152 Fabric Care Temperature Switch 3399643 3399643 3399643 Motor Relay 3405281 3405281 3405281 Heater Relay 3405281 3405281 3405281 Even Heat Control Assembly 3976627 3976627 3976627 Timer Knob and Skirt 3402598 3402597 3402595 Console Harness 3976590 3976590 3976590 Main Harness 8299935 8299935 8299935 Door Switch 3392266 3392266 3392266 Thermal Fuse 3390719 3390719 3390719 Gas Burner As...

Page 5: ...ER HI P3 1 HEATER LOW RED COM NO R W R W LOUD BLUE P2 7 BLUE PK BK PTS MOTOR RELAY PK BK BU BLK BU BLK COM NO MOTOR START START SENSE BU BK P1 5 RED WHITE RED CENTRIFUGAL SWITCH P4 5 P4 4 WET W R P4 8 DAMP BLK P4 6 COOL DOWN W BL P4 7 W V P4 3 P4 2 P4 1 BLK BLK L1_ RETURN W R WH BLUE Gas Dryer Wiring Diagram IMPORTANT Electrostatic static electricity discharge may cause damage to electronic contro...

Page 6: ... SWITCH RED WHITE 5M 6M THERMISTOR RED THERMAL FUSE 196 F HIGH LIMIT THERMOSTAT 205 F TEMP NEUTRAL P2 3 P2 1 NC 3M D D2 D1 RED WHITE WHITE WHITE RED W R 3V BLUE 1V HS1 HS2 TF1 TF2 EVEN HEAT CONTROL HEATER RELAY P3 2 HEATER HI P3 1 HEATER LOW RED COM NO R W R W BLUE CENTRIFUGAL SWITCH HEATER STRIP CIRCUIT BLACK L1 LINE WHITE N NEUTRAL EVEN HEAT CONTROL NEUTRAL TERMINAL LINKED TO CABINET MOIST GND M...

Reviews: