Wheaton OmniSpense ELITE Series Instruction Manual Download Page 5

WHEATON

®

 OmniSpense

®

 ELITE Peristaltic Pump

 

 

 
 

 

 

WHEATON | 800.225.1437 (U.S. & Canada Only) | 856.825.1100 | 

www.wheaton.com

 | P/N 50099067 Rev. 5/15/12 WMAN_001 

 

General Safety Rules 

  

WARNING.

 

READ  AND  UNDERSTAND  ALL  INSTRUCTIONS. 

Failure  to  follow  all 

instructions listed below may result in electrical shock, fire and / or serious personal injury. 

 

SAVE THESE INSTRUCTIONS 

1.   Know your instrument

 - Read the operating manual carefully. Learn the equipment's application and 

limitations. 

2.   Ground  all  equipment

  -  If  electrical,  this  instrument  is  equipped  with  a  grounding  type  plug.  The 

green/yellow  conductor  in  the  cord  is  the  grounding  wire  and  should  never  be  connected  to  a  live 

terminal. 

3.   Avoid  dangerous  environment

  -  Electrical  instruments  designed  to  process  liquids  must  be 

operated with extreme caution. If liquid comes in contact with internal electrical components or wires, 

fire or electrical shock may occur. Adequate surrounding work space should be provided during use. 

Do not operate electrical instrumentation in a combustible atmosphere. 

4.   Work surface

 - Keep well lighted. Be certain the work surface is clean, level and sturdy enough to 

support the weight of the unit, particularly if it is to be filled with liquid. 

5.   Wear  proper  apparel  -

  Do  not  wear  loose  clothing,  neckties  or  jewelry  that  might  get  caught  in 

moving parts. Non-slip footwear is recommended. Wear protective hair covering to contain long hair. 

6.   Wear  safety  goggles 

-  Wear  safety  goggles  at  all  times.  Everyday  eyeglasses  only  have  impact 

resistant lenses, they are NOT safety glasses. 

7.   Don’t Overreach 

- Keep proper footing and balance at all times.

 

8.   Maintain instrument with care 

- Keep screws tight and unit clean. Check periodically for worn or 

damaged parts. Inspect the plug and cord before each use. Do not operate this instrument if there are 

signs of damage. 

9.   Avoid accidental start up 

- If electrical, always make sure the switch is in the "OFF" position before 

plugging instrument into outlet. 

10. Disconnect Instrument 

- Always disconnect the instrument from the power source before servicing. 

11. Do not block cooling vents if provided. 
12. Do not operate this equipment in any manner not specified in this manual.  
13. It  is  recommended  that  a  fire  extinguisher  always  be  located  in  areas  where  electrical 

instruments are being used. 

 

 

Specific Safety Considerations 

 

 

WARNING!  IMPROPER GROUNDING CAN RESULT IN ELECTRICAL SHOCK.  IN THE 

EVENT OF A SHORT CIRCUIT, GROUNDING REDUCES THE RISK OF SHOCK.   THIS 

INSTRUMENT MUST BE GROUNDED.

 

 

This instrument is equipped with a cord having a grounding wire and an appropriate grounding plug.  The 

plug must be used with an outlet that has been installed and grounded in accordance with all local codes 

and ordinances. The outlet must have the same configuration as the plug.  

DO NOT USE AN ADAPTER.

 

Summary of Contents for OmniSpense ELITE Series

Page 1: ...WHEATON 800 225 1437 U S Canada Only 856 825 1100 www wheaton com P N 50099067 Rev 5 15 12 WMAN_001 Catalog Numbers W375030 A and W375030 B 100 120V And W375030 C through W375030 J 220 240V...

Page 2: ...terface 5 3 Performance Highlights 6 0 Installation 6 1 Input Power Requirements 6 2 Power Cord Set 7 0 Initial Startup and Operation 7 1 Pump Head Attachment and Tubing Installation 7 2 Tubing Charac...

Page 3: ...gs 12 0 Constant Flow Rate Dispensing 12 1 Constant Flow Rate 12 2 Soft Start Ramping 12 3 Changing Flow Rate On The Fly 13 0 Working with Alternate Pump Head Setups 13 1 Multiple Pump Heads 13 2 Work...

Page 4: ...of identifying such a problem by calling Customer Service at 800 225 1437 U S Puerto Rico and Canada or Internationally at 856 825 1100 and then providing the Model Serial and Catalog Number of the p...

Page 5: ...t caught in moving parts Non slip footwear is recommended Wear protective hair covering to contain long hair 6 Wear safety goggles Wear safety goggles at all times Everyday eyeglasses only have impact...

Page 6: ...pumphead 7 H x 8 W x 13 D in 17 8H x 22 3W x 33 0D cm Weight 11 8 lbs 5 4 kg Available Wheaton Tubing Sizes 2 3 6 8 mm ID Maximum Dispense Range for All Tubing Sizes 01 9999 99 ml Approximate Flow Rat...

Page 7: ...Initial Inspection When you receive your new OmniSpense ELITE inspect it for any obvious damage that may have occurred during shipment If any damage is found notify the carrier at once Warranty inform...

Page 8: ...adjustable delay can be set from 0 5 to 99 9 seconds between doses to accommodate user dexterity and work load The pump can be activated by depressing either the front panel mounted start key or the o...

Page 9: ...ting plate Place the pump head on the mounting plate and twist the pump head clockwise until it clicks into place Tubing Installation Insert Tubing into the pump head between the pump head cover and t...

Page 10: ...3 Switching the Unit ON Switch the pump ON via the power switch on the rear panel The main screen displays the Wheaton Industries logo and the firmware version level The pump will automatically trans...

Page 11: ...a Pump Running Pump Stopped indicator Pins 1 footswitch and 2 footswitch GND are 5V TTL compatible inputs with pull up resistors and can be driven by an isolated open collector device or dry contact...

Page 12: ...ON will cause the unit to sound an end of dispense alert Turning the buzzer function OFF shown will disable the buzzer during the dispense cycle 8 3 Unit Reset Press the UP and DOWN and the LEFT and R...

Page 13: ...Cassette Pump Model 304 308 9 2 Pump Direction Use the UP and DOWN keys to move to the pump direction icon Use the LEFT and RIGHT arrow keys to select either clockwise or counterclockwise direction C...

Page 14: ...n The PRIME button on the keypad now becomes active Push and HOLD the prime button on the keypad to run the pump motor and purge any air from the tubing RELEASE the prime button to stop the motor 10 3...

Page 15: ...olume Press OK to enter the volume and complete the calibration procedure Press OK again to return to the HOME screen 11 0 Making Batch and Single Dose Dispenses From the HOME screen press OK to navig...

Page 16: ...RIGHT keys to enter volume per dispense Press OK when done 11 4 Delay Between Dispenses Use the UP and DOWN keys to navigate to the Delay icon Use the UP and DOWN and the LEFT and RIGHT keys to enter...

Page 17: ...k Volume set to 5 mL Use the UP and DOWN and the LEFT and RIGHT keys to enter the drawback volume Press OK when done 11 6 Soft Start Ramping Use the UP and DOWN keys to navigate to the Ramp icon Press...

Page 18: ...uring a batch dispense by pressing the Start Stop button and then using the UP and DOWN and the LEFT and RIGHT keys to enter the dispense volume Press OK when done Press the Start Stop button to resum...

Page 19: ...800 225 1437 U S Canada Only 856 825 1100 www wheaton com P N 50099067 Rev 5 15 12 WMAN_001 19 Flow Mode Press OK to navigate to the FLOW SET UP screen Set Flow Rate Maximum attainable flow rate base...

Page 20: ...The Fly The flow rate can be changed while the unit is running by using the LEFT and RIGHT keys to navigate to the running flow rate then using the UP and DOWN and the LEFT and RIGHT keys to enter th...

Page 21: ...th Y couplers into a single outlet The combined volume of the two pump heads is used in the calibration number Running two pump heads as two independent processes is not recommended as a single calibr...

Page 22: ...quickly recalled and the pump made ready for a particular operation 14 1 To Store a Parameter Set all pump parameters to desired settings Navigate to the HOME screen and select the storage icon Use th...

Page 23: ...vide a different liquid delivery range when used in conjunction with the pump unit Accuracy is increased as the number of pump head revolutions required per dispense is increased Tubing size should be...

Page 24: ...cy ramp rates should be set to as long as can be tolerated as a long ramp rate will naturally lengthen the dispense cycle time 15 3 Using Multiple Pump Heads Successful use of multiple pump heads depe...

Page 25: ...d warm air Although the OmniSpense ELITE is designed for easy service it is highly recommended that the instrument be returned to Wheaton Industries should any major repairs be needed Pump rollers can...

Page 26: ...mbly Motor fails to maintain constant rotation speed Cause Motor control board defective Remedy Have defective control board replaced Cause Drive motor defective Remedy Have defective motor replaced L...

Page 27: ...unit 3 Replace with new fuses 108 120 vac unit use 2 5x20mm 250V 2 0 AT fuses be sure the correct cord set is used 220 240 vac unit use 2 5x20 mm 240V 1 0 AT fuses be sure the correct cord set is use...

Page 28: ...istaltic Pump WHEATON 800 225 1437 U S Canada Only 856 825 1100 www wheaton com P N 50099067 Rev 5 15 12 WMAN_001 28 FIGURE A Major Component Identification Display Keypad Pump Head Remote I O Connect...

Page 29: ...1 50029919 NUT HEX 6 32 16 1 I052273 WASHER STAR 6 INT TOOTH 17 1 50099063 STF 6 32 X 1 4 ALUMINUM 18 2 WI056864 FUSE 5X20MM 2 0AT 250V 120V 18 2 WI056862 FUSE 5X20MM 1 0AT 250V FIGURES C THRU E Uppe...

Page 30: ...WHEATON OmniSpense ELITE Peristaltic Pump WHEATON 800 225 1437 U S Canada Only 856 825 1100 www wheaton com P N 50099067 Rev 5 15 12 WMAN_001 30...

Page 31: ...WHEATON OmniSpense ELITE Peristaltic Pump WHEATON 800 225 1437 U S Canada Only 856 825 1100 www wheaton com P N 50099067 Rev 5 15 12 WMAN_001 31...

Page 32: ...WHEATON OmniSpense ELITE Peristaltic Pump WHEATON 800 225 1437 U S Canada Only 856 825 1100 www wheaton com P N 50099067 Rev 5 15 12 WMAN_001 32...

Page 33: ...WHEATON OmniSpense ELITE Peristaltic Pump WHEATON 800 225 1437 U S Canada Only 856 825 1100 www wheaton com P N 50099067 Rev 5 15 12 WMAN_001 33...

Page 34: ...WHEATON OmniSpense ELITE Peristaltic Pump WHEATON 800 225 1437 U S Canada Only 856 825 1100 www wheaton com P N 50099067 Rev 5 15 12 WMAN_001 34...

Page 35: ...device described below marked with CE fulfills the relevant fundamental EMC and safety requirements specified by the appropriate EU Directive with respect to the design and construction of the commer...

Reviews: