Water Heater  

 

4.10 Assessment and replacement of electric element AK1225, AK1224

 

The failure of the electric element will be noted by the lack of hot water when operating the Water 
Heater  in  the  electric  mode  or  in  increase  heat  up  times  in  the  combined  mode.  The  fault  can 
establish itself in two ways: 
- no hot water available and Water Heater Control Panel indicates overheat fault 
- no hot water available and no fault indicated 
To  assess  which  of  the  faults  occurred  and  to  take  the  correct  action,  please  follow  the  steps 
outlined in Figure 18. 

Figure 18 

 Electric element assessment and replacement procedure  

 

-  unplug spark electrode from PCB at 

connection J7

 

-  replace spark electrode as shown 
-  ensure  spark  electrode  is  secure  in 

ceramic 

 if loose, replace.

 

-  secure  with  self-tapping  screw 

included

 

-  before securing the spark electrode 

cable  to  the  gas  pipe,  ensure  the 
plastic sleeve is pulled towards  the 
spark electrode to avoid arcing with 
adjacent metal components

 

-  secure  cable  to  gas  pipe  using 

cables ties included

 

-  plug electrode cable into PCB 

 J7 

-  re-assemble  the  insulation  and 

front cover 

-  recommission system (see 4.12)

 

5

 

6

 

7

 

8

 

9

 

4

 

! Ensure 230V supply is isolated before commencing work on the product.

 

No  hot  water  available  and  Water  Heater  Control  Panel 
indicates overheat fault: 

- this fault indicates that the electric element is still operating but 

could be heavily contaminated with lime scale build up 

 allow Water Heater element to cool. 

 descale  Water  Heater  using  a  suitable  descaling 

product. 

 clear lockout on Control Panel. 

 then attempt to heat water. 

Should  the  fault  persist,  please  check  the  mains 
connections as shown. 

No  hot  water  available  and  no  fault  indicated  on  Water 
Heater Control Panel:

 

-  this  fault  indicates  that  the  electric  element  is  either  not 

connected correctly or faulty and does no longer operate 

-  remove cover as shown in Chapter 4.6 

1

  Confirm mains cable connections are as shown. 

2

  Confirm PCB to electric element connections are 

as shown. 

 

 

Summary of Contents for WH/WI0802

Page 1: ...466 421 info whalepumps com www whalepumps com Page 1 of 32 Water Heater Whale Water Heater WH WI How To Guide Note Images shown are for illustration purposes only This document is solely for guidance...

Page 2: ...5 Flashes Bars Water Heater issues 16 4 1 2 Clear lockout procedure iVan Control Panel 16 4 1 2 1 Heaters manufactured BEFORE mid 2016 17 4 1 2 2 Heaters manufactured AFTER mid 2016 Heaters with rese...

Page 3: ...aters listed as compatible The Whale Water Heaters these instructions are applicable to are Figure 1 Product range covered in this How to Guide Water heater part number Description WH0802xx Water Heat...

Page 4: ...and damage caused by the system being installed by untrained or incompetent personnel For Gas Products Installation servicing and repair under warranty of this appliance must only be carried out by co...

Page 5: ...Water Heater must be fully drained This is particularly important during the winter months as a precaution against freezing To drain switch off the water pump at either the pump switch or main switch...

Page 6: ...re mbar 28 30 30 37 connection mm 8mm compression fitting consumption g h 90 heat input kW 1 25 DC power voltage V 10 4 12 0 14 5 current operation A standby A 0 7 0 01 AC power voltage V 230 N A 230...

Page 7: ...mersible pump or an on board pump The supply pressure to the Whale WH Water Heaters must not exceed 1 9bar and the cold feed must be equipped with a non return valve to avoid warm water back feeding i...

Page 8: ...en by the user with all control panels The water can reach temperatures more than 70 C Should there be a risk of scalding a thermostatic mixing valve must be used to ensure safe operation of the hot w...

Page 9: ...1 Flash Chapter 4 1 1 3 No flame detected 2 Flashes Chapter 4 1 1 4 Overheat 3 Flashes Chapter 4 1 1 5 Low high voltage supply 5 Flashes Chapter 4 1 1 6 Other internal fault Gas related issues Smell...

Page 10: ...5 Chapter 4 3 Correct supply voltage issue Polarity JST loom connections Chapter 4 4 Return Heater to Whale Chapter 4 2 Correct gas type 5 C use Propane Change gas bottle to Propane Correct gas press...

Page 11: ...rom PRV drain valve Cold water connection From Water Heater Valve open Heater operating Close valve Wait for heat up process to finish Replace PRV drain valve Chapter 4 5 1 Replace connection fitting...

Page 12: ...onent related issues Click Click tick sound Heater working See Lockout fault codes above Heater switch ON 12 V DC ok After repeats Heater locks out red LED flashing Check DC fuse Chapter 4 3 Check O H...

Page 13: ...Panel working iVan Panel working See user instructions No display on iVan Panel Press screen home button Check 12V supply to iVan Panel Chapter 4 11 Check Water Heater settings on iVan Panel Fault fi...

Page 14: ...6a Figure 6a Clear lockout procedure Analog and Duo Control Panel 4 1 1 2 Heaters manufactured AFTER mid 2016 heaters with reset button If the Water Heater lockout condition has been identified by 3 o...

Page 15: ...ry to operate the Heater again on gas If this has not solved the issue proceed to next stage Connect a regulated supply directly to the heater to check if system fault exists Check the Flue if compete...

Page 16: ...ight and have a sound connection Check output from PSU and the wire gauge is correct Have either a generator motor mover been in use Where two batteries are fitted ensure they are correctly wired in p...

Page 17: ...on instead Please refer to chapter 4 1 1 3 for additional recommended checks Check water supply The Water Heater is not completely full of water Run the Pump with one hot tap open until water flows sm...

Page 18: ...for additional recommended checks Air pressure fault 5 Check the flue ends outside the vehicle and clear any obstructions away from them When the check is complete turn the Master Switch off then on a...

Page 19: ...etails Name Initial s Address Telephone Mobile Fax e mail 1 Date of Claim dd mm yy CLAIM 1 CLAIM 2 CLAIM 3 2 End user details Name Initial s Address 3 Installation type Domestic Marine RV Make model 1...

Page 20: ...olarity will damage the internal PCB fuse on PCB Equipment Low resistance multimeter set to DC Voltage 12V DC power supply connected Step 1 insert meter probes into Water Heater 8 way connector block...

Page 21: ...on and the voltage that should be read when the 12V DC power supply is connected and the Heater is switched on Figure 11 loom connections check Correct polarity DC fuse If the fuse is faulty please re...

Page 22: ...fit drain hose to PRV re commission system see 4 12 1 2 3 Drain down Water Heater before replacing cold water connection remove clear drain hose from PRV outlet and retain for further use to remove P...

Page 23: ...emove 8 way connector block from Water Heater Close gas supply Isolate 230V supply Step 1 Remove top and bottom assembly screws using a Pozi 2 screwdriver and slide front cover along hot water outlet...

Page 24: ...he O H stat can be checked directly at the device as shown or on the connectors when removed from the PCB as indicated Testing on the device is preferable as it eliminates potential faults in the wiri...

Page 25: ...be checked without removing it from the Water Heater It can be checked by unplugging it from the PCB following the steps shown below remove thermistor plug from PCB measure resistance of Thermistor ap...

Page 26: ...luded before securing the spark electrode cable to the gas pipe ensure the plastic sleeve is pulled towards the spark electrode to avoid arcing with adjacent metal components secure cable to gas pipe...

Page 27: ...ter to check resistance measurement across live and neutral as shown Should the above not resolve the issue 1st check resistance of electric element 2nd replace electric element compare measured value...

Page 28: ...ns Chapter 4 6 Re pair see instructions Open Water Heater to access coms PCB OFF ON Status of LED on PCB FLASH Paired ok Not paired Check all cable connections to PCB incl crimp and solder connections...

Page 29: ...listed in Figure 21 are available as spare parts to address the various issues that might occur when operating the Water Heater Figure 21 Spare parts Water Heater Item number Description Image AK1202...

Page 30: ...of 32 Water Heater AK1210 WtrHtr 8L G E Temp Sens M5 AK1211 WtrHtr 13L G E Temp Sens M5 AK1212 WtrHtr 13L Gas OH Stat AK1213 WtrHtr 8L Gas OH Stat AK1215 WtrHtr 8 13L Flue Cover White AK1217 WtrHtr G...

Page 31: ...reland tel 44 0 2891 270 531 fax 44 0 2891 466 421 info whalepumps com www whalepumps com Page 31 of 32 Water Heater AK1224 WtrHtr ElctrElmnt Assy 1 2kW AK1225 WtrHtr ElctrElmnt Assy 1 5kW AK1226 WtrH...

Page 32: ...erence by Whale Approved Service Engineers when servicing or repairing Whale Water Heaters Copyright Whale 2018 All rights reserved Reproduction in whole or in part without permission is prohibited WH...

Reviews: