3.4
Installation
3.4.1
Preparing for the installation
Check that there is sufficient room for the machine at the installation location.
•
Check that correct connections are available for water, electricity, drainage
and possibly steam at the installation location. See TECHNICAL SPECIFI-
CATIONS.
•
Check that the overheating protection device is reset.
3.4.2
Positioning the machine
Check the following points before the machine is placed in position:
•
Check that the fuse for the machine at the site is off, blocked and that out-
going electrical circuits from the machine are non-live.
•
Remove the protective plastic on the sides which are to be stood against a
wall.
•
If holes need to be drilled in the machine, the holes must be fitted with an
edge strip or similar protection.
•
Lift the machine off the pallet by opening the door and lifting internally to-
gether with a counterstay at the back of the machine. The machine should
NOT be lifted by the handle.
•
Put the machine in position and check that it is horizontal using a spirit lev-
el. Use the legs to adjust the machine height (+ 55mm). Once the machine
has been filled with water, do another check to make sure the machine is
standing level.