WD-215T
Rev. 6.0 (201812)
Installation instructions
15
Connection of the equipment
The machine is ready for fitting detergent and drying agent equipment, but this is
not included in the delivery. To avoid making unnecessary holes in the machine,
the equipment should be placed on the wall behind the machine.
Connections for detergent and drying agent dosage.
1.
Water outlet for detergent dosage on the incoming hot water pipe
2.
Terminal box with connections for control of detergent and drying agent.
3.
Plugged hole in the cover plate on the back of the machine for alternative
detergent connection. Drill a hole from the back of the chemical washing
tank through the plugged hole.
4.
Plugged hole ø 22 mm for measuring cell on the front of the chemical wash
tank.
5.
Plugged connection ø 11 mm for liquid detergent on the front of the chemi-
cal washing tank.
6.
Plugged connection ø 18 mm for connecting hose for detergent in solid
form.
7.
Connection for drying agent dosage by the booster heater.
8.
Hole ø 25 mm for hose intended for detergent in solid form.
9.
Hole ø 19 mm for drying agent hose.
WD215T_4_R1
6
1
9
8
7
5
4
3
2
Summary of Contents for WD-215T