38
5. Measurement Functions and Ranges
DC Voltage Measurement
Range Resolution
Accuracy
200 mV
0.1 mV
2 V
1 mV
20 V
10 mV
200 V
100 mV
± 0.5 % MV.* ±1 Dg.**
1000 V
1 V
± 0.8 % MV. ±2 Dg.
- Input Resistance: 10 M
Ω
- Maximum Input Voltage: 750V AC resp. 1000 V DC Voltage
DC Voltage Measurement
Range Resolution
Accuracy
2 V
1 mV
20 V
10 mV
200 V
100 mV
± 0.8 % MV. ±3 Dg.
750 V
1 V
± 1.2 % MV. ±3 Dg.
- Input Resistance: 10 M
Ω
/ The given values are for frequencies from 40 to
400 Hz (under 500 V the range is 40 - 100 Hz)
- The Root Mean Square Value is displayed.
- Maximum Input Voltage 750 V AC or 1000 V DC respectively.